DISPLAY
ENTRY
P29
STOP input (terminals J3/J4) function:
AUS
● The STOP input is deactivated.
St.Er
● The STOP command stops the gate. With the next START command,
the gate moves in the opposite direction.
St.Gr
● The STOP command stops the gate. With the next START command,
the gate continues in the same direction.
P30
PHOTO 1 function (internal light barrier, type 1, terminals J5/J9):
JA
● Safety input activated.
AUS
● Safety input deactivated.
P31
PHOTO 2 function (external light barrier, type 2, terminals J6/J9):
ZUPA
● Safety input active on closing and stationary gate.
AUS
● Safety input deactivated.
ZU
● Safety input activated only on closing.
P32
JA/nEin
Testing of PHOTO 1 and PHOTO 2 light barriers.
P33
JA/nEin
Safety input 1 (terminals J7/J9) for safety contact strip in open direction
activated.
P34
JA/nEin
Safety input 2 (terminals J8/J9) for safety contact strip in close direction
activated.
P35
Testing/evaluation of safety contact strips:
nEin
● External evaluation with normally closed contact, without testing.
8.2
● Integrated evaluation for 8k2 safety contact strips.
rEL
● External evaluation with normally closed contact, with testing.
P39.o
1.0 A - 16.0
Obstacle sensor (current value) in open direction,
A
see also "Obstacle sensor in the open direction" on page 25.
nEin
Obstacle sensor deactivated.
P39.c
1.0 A - 16.0
Obstacle sensor (current value) in close direction,
A
see also "Obstacle sensor in the close direction" on page 25.
nEin
Obstacle sensor deactivated.
P40.o
1 - 7
Obstacle sensor (speed monitoring) in open direction,
see also "Obstacle sensor in the open direction" on page 26.
0
Obstacle sensor deactivated.
P40.c
1 - 7
Obstacle sensor (speed monitoring) in close direction,
see also "Obstacle sensor in the close direction" on page 26.
0
Obstacle sensor deactivated.
P42
Function of option relay
t.Im,
● Relay switched on for set time.
0.5ʺ - 20.0ʹ
AUS
● "Relay switched on for set time" function deactivated.
t.LiC,
● Relay is switched on when gate is moving and switches off (delayed)
0.5ʺ - 20.0ʹ
after set time.
SL
● Signal light function, see also "Warning/signal light output
function" on page 27.
P43
Radio receiver channel 2 function:
Stan
● Pedestrian opening.
TiM
● Timer function, option relay switches on for time set in menu P42.
biSt
● Bistable function, option relay changes switching status on each
command.
Mon
● Monostable function, option relay switches on for duration of
command.
P44
Warning light output 24 V function.
AUS
● Function deactivated
bL
● Flashing
SL
● Signal light
35
DESCRIPTION
ENGLISH
STANDARD VALUE
AUS
AUS
AUS
nEin
nEin
nEin
nEin
nEin
nEin
0
0
t.iM, 1.0ʹ
Stan
AUS
Set value

Advertisement