Display
(fl ashing) Info
Message appears after
F15
a start command.
Message appears after
F20
a start command in
open direction or during
opening.
Message appears after
F26
a start command in
close direction or during
closing.
Message appears after
F27
a start command in
close direction or during
closing.
Note: The automatic gate closing function is locked and must be restarted by a start command.
Message appears after
F31
a start command or
when gate moving.
Message appears after
F32
a start command in
open direction or during
opening.
Message appears after
F33
a start command.
Message appears after
F37
a start command.
Message appears after
F38
a start command.
Error/warning
Possible cause
Error when testing
CLOSE closing edge protection was
CLOSE closing edge
active during testing.
protection.
Closing edge protection was activated,
but no closing edge protection is
connected.
Incorrect evaluation type set.
The closing edge protection input has
been short-circuited with a wire jumper.
Force shutdown during
The gate is running sluggishly/unevenly
gate opening
There is an obstacle in the gate area
Force shutdown during
The gate is running sluggishly/unevenly
gate closing
There is an obstacle in the gate area
5x force shutdown or
The gate is running sluggishly/unevenly
closing edge protection
in succession during
gate closing.
There is an obstacle in the gate area
(Error indicator only
appears if automatic
The closing edge protection is defective
gate closing is selected).
Light barrier type 1 was
Light barrier at terminals J5 and J9
active.
was interrupted or actuated, see "7.24
Photocell 1 input (terminals J5/J9)" on
page 24.
OPEN closing edge
Closing edge protection at terminals
protection was active.
J7 and J9 was interrupted or actuated,
see "7.27 Closing edge protection
1 (terminals J7/J9) input" on page
24.
Incorrect evaluation activated, see
"7.29 Evaluation of the closing edge
protection" on page 25.
Error when testing
OPEN closing edge protection was active
OPEN closing edge
during testing.
protection.
Closing edge protection was activated,
but no closing edge protection is
connected.
Incorrect evaluation type set.
The closing edge protection input has
been short-circuited with a wire jumper.
Error when testing light
Light barrier was active during testing.
barrier type 1
A light barrier was activated, but no light
barrier is connected.
The light barrier input has been short-
circuited with a wire jumper.
Error when testing light
Light barrier was active during testing.
barrier type 2
A light barrier was activated, but no light
barrier is connected.
The light barrier input has been short-
circuited with a wire jumper.
33
ENGLISH
Remedy
Check connection and function of closing
edge protection and associated evaluation
device.
Deactivate closing edge protection in menu
P34. See Page 24.
Set correct evaluation type in menu P35.
See "Evaluation of the closing edge
protection" on page 25.
Remove wire jumper, connect closing edge
protection and corresponding evaluation
device or deactivate closing edge protection
in menu P34 if not present.
Correct gate run, teach in opener again if
necessary or adjust value in menu P39.o
or P40.o.
Remove obstacle.
Correct gate run, teach in opener again if
necessary or adjust value in menu P39.c
or P40.c.
Remove obstacle.
Correct gate run, teach in opener again if
necessary or adjust value in menu P39.c
or P40.c.
Remove obstacle.
Check the closing edge protection and
replace if necessary. The opener must be
restarted by a command.
Remove obstacle which triggered the light
barrier and/or check and replace the light
barrier if necessary.
When no light barrier is connected, menu
P30 must be set to AUS.
Remove obstacle which triggered the
closing edge protection and/or check and
replace the closing edge protection/supply
line if necessary.
When no closing edge protection is
connected, menu P33 must be set to nEin.
Set correct evaluation in menu P35.
Check connection and function of closing
edge protection and associated evaluation
device.
Deactivate closing edge protection in menu
P33. See Page 24.
Set correct evaluation type in menu P35.
See "Evaluation of the closing edge
protection" on page 25.
Remove wire jumper, connect closing edge
protection and corresponding evaluation
device or deactivate closing edge protection
in menu P33 if not present.
Check light barrier or supply line to light
barrier and replace if necessary.
Remove obstacle.
Deactivate light barrier in menu P30. See
Page 24.
Remove wire jumper and deactivate light
barrier in menu P30. See Page 24.
Check light barrier or supply line to light
barrier and replace if necessary.
Remove obstacle.
Deactivate light barrier in menu P31. See
Page 24.
Remove wire jumper and deactivate light
barrier in menu P31. See Page 24.