DYNAMIC MOTION system
DMUI-HSM
User Manual
PART
OF
DYNAMIC MOTION

Advertisement

Table of Contents
loading

Summary of Contents for LOGICDATA DYNAMIC MOTION DMUI-HSM

  • Page 1 DOCUMENT VERSION 1.0 | JANUARY 2020 DYNAMIC MOTION system DMUI-HSM User Manual PART DYNAMIC MOTION...
  • Page 2 DMUI-HSM - MANUAL // PAGE 2 DMUI-HSM - Operating Manual Document Version 1.0 / January 2020 This document was originally published in English. LOGICDATA Electronic & Software Entwicklungs GmbH Wirtschaftspark 18 8530 Deutschlandsberg Austria Phone: +43 (0) 3462 51 98 0 Fax:...
  • Page 3: Table Of Contents

    DMUI-HSM - MANUAL // PAGE 3 CONTENTS General information Other applicable documents Copyright Royalty-free use of images and text Trademarks Safety Target audience General safety regulations and obligations Intended use Reasonably foreseeable misuse Explanation of symbols and signal words Liability Residual risks Skilled Persons Notes for Resellers...
  • Page 4: General Information

    Height-Adjustable Table Systems. The license does not include logos, designs, and page layout elements belonging to LOGICDATA. The Reseller may make any necessary changes to the text and images to adapt them for the purpose of end user documentation. Texts and images may not be sold in their current state and may not be published or sublicensed digitally.
  • Page 5: Safety

    • Do not remove, change, bridge, or bypass any protection, safety, or monitoring equipment • Do not convert or modify any components without written approval from LOGICDATA • In the event of malfunction or damage, faulty components must be replaced immediately •...
  • Page 6: Explanation Of Symbols And Signal Words

    2.6 LIABILITY LOGICDATA products comply with all currently applicable health and safety regulations. However, risk can result from incorrect operation or misuse. LOGICDATA is not liable for damage or injury caused by: • Improper product use • Disregard of the documentation •...
  • Page 7: Residual Risks

    DMUI-HSM - MANUAL // PAGE 7 2.7 RESIDUAL RISKS Residual risks are the risks that remain after all relevant safety standards have been complied with. These have been evaluated in the form of a risk assessment. Residual risks associated with assembly and instal- lation of DMUI-HSM Handsets are listed here and throughout this Operating Manual.
  • Page 8: Notes For Resellers

    DMUI-HSM - MANUAL // PAGE 8 2.9 NOTES FOR RESELLERS Resellers are companies that purchase LOGICDATA products for installation in their own products. INFO For reasons of EU conformity and product safety, Resellers should provide end users with an Operating Manual in their native EU official language.
  • Page 9: Product

    DMUI-HSM - MANUAL // PAGE 9 5 PRODUCT Fig.1 shows a standard model of the DMUI-HSM. The exact variant of the DMUI-HSM is denoted by the prod- uct's order code. Consult the accompanying datasheet to ensure that you have received the correct variant. KEY PRODUCT FEATURES Mounting Points UP / DOWN Keys...
  • Page 10: Dimensions

    DMUI-HSM - MANUAL // PAGE 10 5.2 DIMENSIONS Length 50.0 mm 1.969 “ Width 59.9 mm | 2.358 " Height (to underside of Table Top) 17.3 mm | 0.681 " 59.9mm 2.358" Fig. 2: Product dimensions, DMUI-HSM...
  • Page 11: Drilling Template

    DMUI-HSM - MANUAL // PAGE 11 5.3 DRILLING TEMPLATE There are two variants for mounting. In the Standard Position the drilled holes should be 8 mm from the front edge of the Table Top and 43.8 mm apart. Alternatively, the drilled holes can be set to the Transportation Postion, 24 mm from the front edge of the Table Top and 43.8 mm apart.
  • Page 12: Assembly

    DMUI-HSM - MANUAL // PAGE 12 6 ASSEMBLY This chapter describes the process of installing the DMUI-HSM Handset into the DYNAMIC MOTION System. SAFETY DURING ASSEMBLY Risk of death or serious injury through electric shocks WARNING DMUI-HSM Handsets are electrical devices. Basic safety precautions must be taken at all times.
  • Page 13: Required Components

    The mounting points for the DMUI-HSM have a width of 4.3 mm. The Mounting Screws should hold the Handset safely and securely in place. Exact specifications can be provided by LOGICDATA on request. 6.3 PROCESS Position the Handset under the table top and mark the position of the Mounting Points.
  • Page 14: System Information

    Remove unnecessary loads from the Table Top Operate the DM System as normal. Green Light Flashing Position Reset Required. Perform a Position Reset Procedure (System Rapidly Manual, Chapter 4.7). Do not operate the DYNAMIC MOTION system if problems persist. Contact LOGICDATA NOTICE for further information.
  • Page 15: Operation

    DMUI-HSM - MANUAL // PAGE 15 8 OPERATION Instructions for operating the system can be found in the DYNAMIC MOTION System Manual. A list of core features can be found below. Handset Keys are represented as follows for further description: UP Key DOWN Key ADJUSTING THE TABLE TOP HEIGHT...
  • Page 16: Additional Information

    Using a DMUI-HSM Handset alongside unauthorized spare or accessory parts may lead to death or serious injury through electric shocks and other hazards. • Only use accessory parts produced or approved by LOGICDATA • Only use replacement parts produced or approved by LOGICDATA •...
  • Page 17 LOGICDATA LOGICDATA North America, Inc. Electronic & Software Entwicklungs GmbH 1525 Gezon Parkway SW, Suite C Wirtschaftspark 18 Grand Rapids, MI 49509 8530 Deutschlandsberg Austria Phone: +43 (0)3462 5198 0 Phone: +1 (616) 328 8841 Fax: +43 (0)3462 5198 1030 Email: office.na@logicdata.net...