Page 2
Please be advised that unit was designed / manufactured for specific applications. So please do not modify and use the unit for any application other than which it was designed for. If you have any questions regarding any applications, please ask Honda dealer before using.
1.SAFETY LABEL LOCATION These labels warn you of potential hazards that can cause serious injury. Read them carefully. If a label comes off or becomes hard to read, contact your Honda dealer for a replacement. EXHAUST CONNECT CAUTION CAUTION READ OWNER’S...
Page 5
Honda generator is designed to give safe and ・ dependable service if operated according to instructions. Read and understand the Owner’s Manual before operating the generator. Failure to do so could result in personal injury or equipment damage. Exhaust contains poisonous carbon monoxide, ・...
– Do not operate the generator with any cover removed. You may get your hand or foot caught in the generator and it may cause accident. – Consult your authorized Honda dealer for disassembly and service of the generator that are not covered in this manual.
Page 7
Electric Shock Hazards The generator produces enough electric power to cause a serious shock or electrocution if misused. • Do not use in wet conditions. Keep the generator dry. – Do not use in the rain or snow. – Do not use near a pool or a sprinkler system. –...
4. CONTROLS Engine switch To start and stop the engine. Switch position: ON:To run the engine after starting. OFF:To stop the engine. OFF Position ON Position Recoil starter To start the engine, pull the starter grip lightly until resistance is felt, then pull briskly. Do not pull the starter grip from control panel side.
Page 13
Fuel valve The fuel valve is located between the fuel tank and carburetor. When the valve lever is in the “ON” position, fuel is allowed to flow from the fuel tank to the carburetor. Be sure to return the lever to “OFF” after stopping the engine. ON Position OFF Position Choke Lever...
Page 14
Circuit Breaker The Circuit breaker will automatically cut off the circuit if there is a short circuit or a significant overload of the generator at the receptacle. If the circuit breaker is OFF automatically, check that the appliance is working properly and does not exceed the rated load capacity of the circuit before ON position to the circuit breaker.
5. BEFORE STARTING ENGINE Be sure to check the generator on a level surface with the engine stopped. Before each use, look around and underneath the engine for signs of oil or gasoline leaks. 1. Fill recommended engine oil to the upper level if the oil is short. 2.
6.OPERATION STARTING THE ENGINE Make sure that all electrical loads from panel receptacles are disconnected. The generator may be hard to start if a load is connected. Turn the fuel valve to the “ON” position. If you want to start operating the choke manually, move the choke lever to the “CLOSED”...
Page 17
Do not allow the starter grip to snap back against the engine. Return it gently to prevent damage to the starter or housing. If you have manually closed the choke, move it to the “OPEN” position as the engine warms up. 2.
7. STOPPING ENGINE Disconnect all electrical loads from panel receptacles. Push the engine switch to the “OFF” position. Turn the fuel valve to the “OFF” position. Never leave an appliance plugged into the generator when you stop the generator as damage could result to the generator and / or appliance.
8. MAINTENANCE Periodic inspection and adjustment of Honda engine & Generator is essential if high-level performance is to be maintained. Regular maintenance will also ensure a long service life. The required service intervals and kind of maintenance to be performed are described on OWNER’S MANUAL.
Page 20
Engine oil Engine oil is a major factor affecting engine performance and service life. Non detergent oils and 2stroke engine oils will damage the engine and are not recommended. Check the oil level BEFORE EACH USE with the generator on a level surface with the engine stopped.
Page 21
Used motor oil may cause skin cancer if repeatedly left in contact with the skin for prolonged periods. Although this is unlikely unless you handle used oil on a daily basis, it is still advisable to thoroughly wash your hands with soap and water as soon as possible after handling used oil. Please dispose of used motor oil in a manner that is compatible with the environment.
Page 22
LEVEL GAUGE Spark plug service Recommended spark plugs: EZ3000CX : BPR6ES(NGK) , W20EPR-U(DENSO) To ensure proper engine operation, the spark plug must be properly gapped and free of deposits. If the engine has been running, the muffler will be very hot. Be careful not to touch the muffler.
Page 23
The gap should be: 0.7mm-0.8mm 0.7mm-0.8mm Check that the spark plug washer is in good condition, and thread the spark plug in by hand to prevent cross-threading. After the spark plug is seated, tighten with a spark plug wrench to compress the washer.
Page 24
Unsnap the air cleaner cover clips, remove CLIP AIR CLEANER COVER the air cleaner cover, and remove the element. Wash the element in a solution of household detergent and warm water, then rinse thoroughly; or wash in nonflammable or high flash point solvent. Allow the element to dry thoroughly.
9. TRANSPORTING AND STORAGE When transporting the generator, turn the engine switch and the fuel valve “OFF”. Keep the generator level to prevent fuel spillage. Fuel vapor or spilled fuel may ignite. Touch a hot engine or exhaust system can cause serious burns or fires. Let the engine cool before transporting or storing the generator.
Page 26
Storage procedure 1) Drain the carburetor by loosening the drain screw. Drain the gasoline into a suitable container. Gasoline is extremely flammable and is explosive under certain conditions. Perform this task in a well ventilated area with the engine stopped. Do not smoke or allow flames or sparks in the area during this procedure.
The following wattage chart is guidance only. Refer to your specific appliance for correct wattage. APPLICABLE MAXIMUM WATTAGE ELECTRICAL EQUIPMENT (W) EZ3000CX MODEL APPLIANCE 50Hz 60Hz...
11. TROUBLE SHOOTING When the engine will not start: Is there fuel in the Refill the fuel tank. tank? Is there enough oil in Add the recommended the engine? oil. Take the generator to Is there a spark from Replace the an authorized your the spark plug? spark plug.
12. SPECIFICATION MODEL EZ3000CX ★ENGINE Model Honda GP200 Displacement Oil alert system Starting System Recoil Oil Capacity ℓ ★GENERATOR System Self-exciting, 2pole, field rotating type Voltage regulation system Phase Single Rated power factor cosφ Insulation Class TYPE Rated Voltage Frequency...
APPENDIX 1. LOOSE PARTS 2. INSTALLATION OF WHEEL KIT...
Page 36
1. LOOSE PARTS Check all loose parts against the following list. Contact your dealer if any of the loose parts shown below are not included with your generator. Type:R, S Ref. No. Description Qty. PLUG PLUG WRENCH SHAFT WHEEL WASHER COVER FLANGE BOLT M8-16 FLANGE NUT M8...
Page 37
Type:REH Ref. No. Description Qty. PLUG PLUG WRENCH SHAFT WHEEL WASHER COVER FLANGE BOLT M8-16 FLANGE NUT M8 STAND SNAP PIN HANDLE OWNER’S MANUAL ④ ③ ① ② ⑦ ⑥ ⑤ ⑧ ⑩ ⑨ ⑪...
Page 38
Type:RK Ref. No. Description Qty. PLUG PLUG WRENCH SHAFT WHEEL WASHER COVER FLANGE BOLT M8-16 FLANGE NUT M8 STAND SNAP PIN HANDLE OWNER’S MANUAL ④ ③ ① ② ⑦ ⑥ ⑤ ⑧ ⑩ ⑨ ⑪...
Page 39
Type:M Ref. No. Description Qty. PLUG PLUG WRENCH SHAFT WHEEL WASHER COVER FLANGE BOLT M8-16 FLANGE NUT M8 STAND SNAP PIN HANDLE OWNER’S MANUAL ④ ③ ① ② ⑦ ⑥ ⑤ ⑧ ⑩ ⑨ ⑪...
Page 40
2. INSTALLATION OF WHEEL KIT 1. Install the stand on the under frame using M8-16mm flange bolts and M8 nuts. 2. Install wheels on the side of frame bracket with shaft and cover. TORQUE : 20.0 – 24.0 N・m FLANGE NUT SNAP PIN WASHER SHAFT...