Memory Function - Niko 05-711 Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 55
05-711
Mode 2: 1-button operation
In the 1-button mode, input 1 and input 2 have different and independent
functions. Input 1 functions as a 1-button dim function, settable with
or without memory. Input 2 allows light atmospheres to be saved
and retrieved at any time. Input 3 allows the panic function to be
activated (see 4.B).
In 1-button mode, the default setting of the analog control is as
follows:
- 1-button operation set with memory function.
If 1-button operation with light atmosphere is used:
- light atmosphere set to max. value.
Operation of input 1 (connection terminals, COM terminal and
terminal 1):
Input 1 has a 1-button dimming function (see fig.1)

Memory function:

You can use the analog control with or without memory. The default
setting of the analog control in 1-button mode is with memory function.
To set the dimmer without memory function, press the control button
for 10s at max. light level. After 10s the light intensity drops from max.
to 50% to confirm that the memory function has been deactivated. Let
go of the push button immediately after this change in light intensity! If
you do not let go of the push button immediately, it will not be possible
to switch from 'with memory' to 'without memory' or vice versa. Repeat
EN