Pacific Scientific 5645 Installation & Hardware Reference Manual page 56

Microstepping indexer / drive
Table of Contents

Advertisement

2.6.1.4 Current Set Up Using Switch S1
The current set up function determines the RMS current supplied
Definition
to the motor. Switches 6, 7, and 8 are required for current set up.
Current set up allows 5645 output to be matched to motor
Benefits
winding.
With the power OFF, select from among the four current values
Procedures
by setting switch positions 6, 7, and 8 as follows:
To set RMS current to ...
5.0 amps
(7.1 amps peak)
(Default factory setting)
6.0 amps
(8.5 amps peak)
7.5 amps
(10.6 amps peak)
8.0 amps
(11.3 amps peaK)
5645 Installation and Hardware Manual
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Move switch SW1 settings to .....
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
5
6
7
8
5
6
7
8
5
6
7
8
5
6
7
8
2 - 47