Download Print this page
Westfire WFUNIQ36 Installation Manual And Operating Instructions

Westfire WFUNIQ36 Installation Manual And Operating Instructions

Advertisement

WESTFIRE·WF36 WF37
WF36 WF37
DK: INST ALLA TIONS- OGBRUGSVEJLEDNING
UK: INST ALLA TION MANUAL AND OPERA TINGINSTRUCTIONS
D: INST ALLA TIONS- UND GEBRAUCHSANWEISUNG
FR: NOTICED' I NST ALLA TION ETD' U TILISA TION
NL: INST ALLA TIEHANDLEIDING ENGEBRUIKSAANWIJZING
DANSKINGENIØRKUNST
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the WFUNIQ36 and is the answer not in the manual?

Questions and answers

Summary of Contents for Westfire WFUNIQ36

  • Page 1 WESTFIRE·WF36 WF37 WF36 WF37 DK: INST ALLA TIONS- OGBRUGSVEJLEDNING UK: INST ALLA TION MANUAL AND OPERA TINGINSTRUCTIONS D: INST ALLA TIONS- UND GEBRAUCHSANWEISUNG FR: NOTICED’ I NST ALLA TION ETD’ U TILISA TION NL: INST ALLA TIEHANDLEIDING ENGEBRUIKSAANWIJZING DANSKINGENIØRKUNST...
  • Page 2: Wf36 Wf37

    WESTFIRE·WF36 WF37 WF36 WF37 DATABLAD/ PRODUCTSHEET/ PRODUKTDATENBLATT/ FICHEPRODUCT Datablad iht. Reglement (EU)2015/1186 Energy Labelling Directive – ( EU) 2015/1186 for Solid Fuel Boilers and Packagesof Solid Fuel Boilers, Supplementary Heaters, Temperature Controls and Solar Devices GemässVerordnung (EU)2015/1186 Fichede produit conformément au réglement (EU)2015/1186...
  • Page 3: Table Of Contents

    WESTFIRE·WF36 WF37 WF36 WF37 DK: INSTALLATIONS-OGBRUGSVEJLEDNING..........4 UK: INSTALLATIONMANUAL AND OPERATINGINSTRUCTIONS....7 INSTALLATIONS-UNDGEBRAUCHSANWEISUNG......19 FR: NOTICED’INSTALLATIONETD’UTILISATION.........22 NL: INSTALLATIEHANDLEIDINGENGEBRUIKSAANWIJZING.....25...
  • Page 4: Installations-Ogbrugsvejledning

    WESTFIREWF36 · WESTFIREWF36 med sokkel WESTFIREWF37 · WESTFIREWF37 med sokkel Vi ønsker Dem tillykke med Deresnye brændeovn fra Westfire ApS.Forat De kan få størst mulig glæde af Deres nye brændeovn og for at der ikke skal opstå problemer, beder vi Dem gennemlæse denne vejledning.
  • Page 5 WESTFIRE·WF36 WF37 SKORSTENSTILSLUTNING Der skal altid anvendes en skorsten med en diameter på min. 15 cm, svarende til en lysning på 175 cm Skorstenenskal have en sådan højde, at trækforholdene er i orden, at røgen ikke generer omgivelserne og skorstenen skal være forsynet med er let tilgængelig renselem.
  • Page 6 WESTFIRE·WF36 WF37 GRUNDINDSTILLING AF SPJÆLDENEUNDERDRIFT : Det er nødvendigt at gøre sine egne erfaringer med hensyn til indstilling af sekundærluft, da f.eksskorstenskvalitet, skorstenshøjde,brændselskvalitet og de ydreforhold spiller en stor rolle, men man kan se om forbrændingen sker på den rigtige måde. Hvis Deresovn indvendig får en belægning af hård blank sod, er der tegn på en ufuldstændig forbrænding, i så...
  • Page 7: Installationmanual And Operatinginstructions

    Thismanual refers to the stove type listed above, which has been tested in accordancewith EN13240. Congratulations on your purchase of a new wood burning stove from Westfire ApS.Pleaseread this manual carefully in order to ensure that you get maximum enjoyment from your new stove and to prevent any problems. Pleasenote that “all local regulations, including those referring to national and EuropeanStandards,need to be complied with...
  • Page 8 Depth 445 mm 445 mm 445 mm Closedcombustion option Order specific closed combustion option STOVEPERFORMANCE& TESTING Westfire UNIQ36/ WF36Pedestal and UNIQ37/ WF37Pedestal have been approved in accordancewith EN13240. Stove model Weight Nominal heat output Wood Smokelessfuels UNIQ36/ UNIQ37 90 kg 7.2 KW...
  • Page 9 The Westfire UNIQ36/ WF36Pedestal and UNIQ37/ WF37Pedestal wood stoves has been tested and is suitable to be installed on a 12 mm non combustible plate such as Westfire 12 mm glass plates or 20 mm slate plates. Installa- tion of all hearths should comply in size and construction so that it is in accordancewith the provisions of the current Building Regulations Approved Document J.
  • Page 10 Connection to chimney Westfire UNIQ36/ WF36Pedestal and UNIQ37/ WF37Pedestal wood stoves has both rear and top flue connector that allows connection to either a masonry chimney or a prefabricated factory made insulated metal chimney in accordancewith the instructions for “Connection to chimney”...
  • Page 11 WESTFIRE·WF36 WF37 Operating your stove – WF36/ WF36 Pedestal and WF37/ WF37 Pedestal WARNING; COAlarm Your installer should have fitted a COalarm in the same room as the appliance. If the alarm sounds unexpectedly, follow the instructions given under “Warning Note” above.
  • Page 12 Door operation When opening the door of your Westfire stove always wear the glove that is provided to protect your hand from possible heat. Thehandle pulls out right away from the fire. When shutting the door push the door closed and push the handle until the handle firmly closes.
  • Page 13 Only specific SEmodels are suitable for smoke control areas, alterations should not be attempted. Westfire smoke control stovesshould not be burnt with the door left open. Therefuelling procedure: - allow the newly charged fuel to burn with the secondaryair control set at maximum for up 3 to 4 minutes.
  • Page 14 Thepaint/ lacquer can wear thin in exposed placesdue to overheating. This,and other lacquer damage, may be repaired using a Westfire Senotherm paint/lacquer spray available from your Westfire dealer. Ash must be stored in a non-combustible container and must not be mixed with other combustible waste.
  • Page 15 WESTFIRE·WF36 WF37 5. Smoke or odour Weakchimney draft checkfor blockagesin the flue pipe/chimney checkthe height of the chimney in relation to the surroundings 6. Sootin the chimney Thefirewood may be too wet intake of secondary air may be insufficient Chimney Fires If the chimney is thoroughly and regularly swept, chimney fires should not occur.
  • Page 16 Theguarantee does not cover damage to replaceable parts, transport costsassociatedwith repairs under warranty or the installation/dismantling of the stove in connection with repairs under warranty. Warning! Any unauthorised modification of the appliance is forbidden. Only replacement parts recommended by Westfire ApSshould be used for repairs...
  • Page 17 WESTFIRE·WF36 WF37 Number Code Description W93700-02-03-99-00 Rearfire brick W93700-02-24-99-00 Right side rear brick Part brick set Left side rear brick Side bricks front x 2 W93700-02-22-99-00 Baseright brick Part brick set Baseleft brick Basefront and rear brick W93700-02-04-99-00 Lower baffle brick...
  • Page 18 WESTFIRE·WF36 WF37 VERMICULITE FIRE BRICK INSTALLATION SEQUENCE – WESTFIREUNIQ36/ WF36 Pedestal and UNIQ37/ WF37 Pedestal PlaceTop baffle in position against L shaped lugs leaving 5 cm gap at rear of stove. Place rear brick Ensureside brick and side bricks in...
  • Page 19: D: Installations-Undgebrauchsanweisung

    Diese Anweisung bezieht sichauf nachfolgend genannte Modelle, die gemäß den Vorschriften der Norm CE/EN13240 geprüft wurden. Wir beglückwünschen Sie zum Erwerb Ihres neuen Westfire Kaminofens. Damit Sie viel Freudedaran haben, bitten wir Sie, diese Gebrauchsanweisungsorgfältig durchzulesen, denn so lassen sich Probleme vermeiden.
  • Page 20 WESTFIRE·WF36 WF37 DasRauchrohrist mit einer Regulierklappe erhältlich, die es ermöglicht, den Schornsteinzugan Tagen mit starkem Wind zu regulieren. Sie darf sich nicht vollständig schließen lassen, d. h., der freie Durchgangmuss mind. 20 cm betragen. Eine Verringerung des Schornsteinzugskann auch auf andere Weise herbeigeführt werden, etwa durch Luftzufuhr im Schornsteinbereich.
  • Page 21 Datum des Kaufs. Die Garantie erstreckt sich nicht auf Schäden,die sich aus Überhitzung durch falsche Bedienung, nicht sachgemäßen Anschlussoder äußere Einwirkungen ergeben. Ausgenommen sind ferner Verschleißteile sowie Kostenfür Transportoder Auf-/Abbauarbeiten im Zugevon Garantie-Reparaturen. Die Garantie erlischt bei unbefugten technischen Änderungen am Ofen. Bei Reparaturen sind ausschließlich von der Fa.Westfire ApSempfohlene Ersatzteile zu verwenden.
  • Page 22: Noticed'installationetd'utilisation

    WESTFIREWF36 · WESTFIREWF36 SOCLE WESTFIREWF37 · WESTFIREWF37 SOCLE Nous vous félicitons pour l’achat de votre nouveau poêle fabriqué par Westfire ApS.Pour en profiter pleinement et vous éviter toute difficulté, nous vous invitons à lire attentivement cette notice. Nousattirons votre attention sur «...
  • Page 23 WESTFIRE·WF36 WF37 Lesmodèles WF36et WF37peuvent être raccordésau conduit de cheminée même lorsque d’autres systèmes y sont aussi raccordés. Lessystèmes au gaz doivent toujours avoir leur propre conduit et aucun autre système ne doit s’y raccorder. CONSEILSD’UTILISATION Lapremière fois que vous faites du feu dans votre poêle, le revêtement réfractaire se solidifie et provoque un dégagement d’odeur et de fumée.
  • Page 24 Lagarantie ne couvre pas les dommages sur des piècesqui peuvent être changées, ni les frais de transport suite à des réparations sousgarantie, ni le montage/démontage des réparations sousgarantie. Avertissement : il est interdit de procéder à des modifications non autorisées de ce système. Encasde réparation, utilisez uniquement des pièces détachées recommandées par Westfire ApS.
  • Page 25: Installatiehandleidingengebruiksaanwijzing

    Dat kan zijn in de vorm van een ventiel (het ventiel moet open staan en over voldoende capaciteit beschikken als de haard brandt) of een verseluchtsysteem dat met de kachel is verbonden. Alle houtkachels van Westfire zijn voorzien van een rookkeerplaat, die ervoor zorgt dat de weg die de rook aflegt lang genoeg is.
  • Page 26 WESTFIRE·WF36 WF37 kanaal. Erkunnen ook andere vormen van afvoerbegrenzers worden toegepast, bijvoorbeeld door buiten de haard om lucht de schoorsteen binnen te laten. WF36/ WF36met sokkel en WF37/ WF37met sokkelkunnen worden aangesloten op schoorstenen waarop ook andere warmtebronnen zijn aangesloten. Gasgestooktewarmtebronnen moeten altijd hun eigen schoorsteen hebben, waarop geen andere warmtebronnen mogen zijn aangesloten.
  • Page 27 De garantie dekt geen schade aan vervangbare onderdelen, transportkosten in verband met garantiereparaties of montage/demontage bij garantiereparaties. De garantie vervalt bij onbevoegde veranderingen aan de warmtebron. Gebruik bij reparatie uitsluitend reserveonderdelen die door Westfire ApSworden aanbevolen.
  • Page 28 WESTFIRE·WF36 WF37 TEST Reg.nr. 300...
  • Page 29 U d d r a g a f r a p p o r t n r. 3 0 0 - E L A B - 2 1 8 7 - E N , E L A B - 2 1 8 7 WA L L o g 3 0 0 - E L A B - 2 1 8 7 - N S Brændeovn; WF 37 og WF 37 med sokkel Emne: WESTFIRE ApS, Tømrervej 3, DK- DK-6800 Varde Rekvirent: Procedure: Prøvning efter DS/EN13240/A2:2004...
  • Page 30 1 til Bekendtgørelse nr. 46 af 22/01-2015 om regulering af luftforurening fra fyringsanlæg til fast brændsel under 1 MW, for så vidt: WESTFIRE2020 v1 | WF36 WF37 TØMRERVEJ3 | DK-6800 VARDE | TELEFON+45 7522 5352 | FAX+45 7522 1352 | WWW.WESTFIRE.DK| E-MAIL: INFO@WESTFIRE.DK...

This manual is also suitable for:

Wfuniq37Uniq37 largeWfuniq36 pedestalWfuniq37 pedestal