5. Shut down Device Configuration Utility and start it
again. This will activate the Cellular tab needed for the
next step.
6. On the Cellular tab, enter the APN provided by your
cellular provider. For standard Telstra SIMs, this will be
telstra.internet.
7. On the Datalogger tab enter the PakBus/TCP Password
twice. This setting specifies a password that will make
the data logger authenticate any incoming or outgoing
PakBus/TCP connection. It must match the value entered
in the Konect PakBus Router setup.
8. Click Apply to save the changes. Verify the settings in the
summary window. (Recommended) Save a copy of the
settings to a file on the computer. Click OK.
9. Click Disconnect and close Device Configuration Utility.
5.3 Set up LoggerNet
The LoggerNet Network Map is configured from the
LoggerNet Setup screen.
NOTE:
Setup has two options, EZ (simplified) and Standard. Click
on the View menu at the top of the Setup screen, and
select Standard view.
From the LoggerNet toolbar, click Main > Setup and configure
the Network Map as described in the following steps:
1. Select Add Root > IPPort.
2. Select PakBusPort and pbRouter for PakBus data
loggers such as the CR800 or CR1000.
NOTE:
PakBus data loggers include the following
models: GRANITE-series, CR6, CR3000, CR1000X,
CR800-series, CR300-series, CR1000, and CR200(X)-
series.
3. Add a data logger to the pbRouter.
4. From the Entire Network, on the left side, select the
IPPort. Enter the Konect PakBus Router DNS address
and port number as noted in the Konect PakBus Router
setup
(Set up Konect PakBus Router
into the Internet IP Address field in the format DNS:Port
with a colon separating DNS and Port. For example,
axanar.konectgds.com:pppp where pppp is the port
number.
5. Leave the default settings for the PakBusPort. PakBus
Port Always Open should not be checked. In the TCP
Password field enter the TCP Password; this must match
the value entered in the Konect PakBus Router setup
and LoggerNet setup.
(p. 2)). Enter them