Download Print this page

Campbell CELL200 Series Quick Deploy Manual page 2

4g lte cellular module for private dynamic ip addresses
Hide thumbs Also See for CELL200 Series:

Advertisement

First-time users need to create a free account. After you submit
your information, you will receive two emails up to five minutes
apart. One email will contain a Passport ID and the other your
Password. If emails are not received, check your email junk
folder.
4.2 Set up Konect PakBus Router
1. Sign in to
www.konectgds.com
and Password found in the two received emails. Once
logged in, you will be at the Welcome page.
2. Click devices and services
the left and select Redeem PakBus Router Code. Enter
your complimentary Router Code found on the
included card with your cellular-enabled device and
click Submit.
3. The next screen shows the assigned DNS address and
Port for the router. Enter a TCP Password and select a
unique PakBus Address for your data logger.
TIP:
Make note of this information; it will be required
for data logger configuration as well as LoggerNet
setup. Please note your DNS, Port, TCP Password
and PakBus address; you will need them later.
using your Passport ID
on the command bar to
5. Hardware and software
configuration
5.1 Set up hardware
1. Connect the cellular antenna, if it is not already
connected. When using a MIMO antenna with multiple
cellular connections, connect the primary cable to
Cellular and the secondary to Diversity. If the cables are
not marked in this way, they can be connected to either
antennna port.
2. Connect your data logger RS-232 or CS I/O port to the
CELL200-series module RS-232 or CS I/O port. Ensure
the same port is used for each device, for example RS-
232 to RS-232. Use an 18663 cable for RS-232
connection or a SC12 cable for CS I/O connection
(either female connector on the SC12 cable can be used
for the CELL220).
3. If not connecting through CS I/O, provide power to the
CELL200 series. The data logger provides power
through the CS I/O port. USB power is not sufficient to
power the CELL200 series; 12 V is required.
5.2 Configure data logger
1. Connect to your data logger by using Device
Configuration Utility.
2. On the Datalogger tab, change the data logger PakBus
Address and PakBus/TCP Password to match the values
entered in the Konect PakBus Router setup.
3. On the Network Services tab in the PakBus/TCP Client
field, enter the DNS address and Port number noted
during the Konect PakBus Router setup.
4. Click Apply to save the changes. Verify the settings in the
summary window. (Recommended) Save a copy of the
settings to a file on the computer. Click OK.
2

Advertisement

loading

This manual is also suitable for:

Cr300-cell220Cell220Cell210