Transport and storage
Transport with lifting strap
Requirements
Bosch Rexroth AG, A4CSG, Series 3x, RE 92105-01-B/06.2017
wARnInG! Danger from suspended loads!
During transport with a lifting device, the axial piston unit can topple out of the
lifting strap and cause injuries.
Use the widest possible lifting strap.
Make sure that the axial piston unit is securely fixed with the lifting strap.
Only guide the axial piston unit by hand for fine positioning and to avoid
oscillations.
Never stand or put your hands under a suspended load.
Place the lifting strap around the axial piston unit in such a way that it neither
passes over the assembled parts (e.g. valves, sensors) nor that the axial piston
unit is hung from assembled parts.
Fig. 6: Transport with the lifting strap

6.2 Storing the axial piston unit

• The storage areas must be free of corrosive materials and gases.
• To prevent damage to the seals, ozone-forming equipment (for example, mercury-
vapor lamps, high voltage equipment, electric motors, sources of electrical sparks
or electrical discharge) must not be operated in storage areas.
• The storage areas must be dry.
Recommended relative humidity ≤ 60%.
• Ideal storage temperature: +5 °C to +20 °C.
• Minimum storage temperature: -40 °C (exception: units with on-board electronics)
• Maximum storage temperature: +60 °C.
• Keep out of direct sunlight.
• Do not stack axial piston units and store them in a shock-proof manner.
• Do not store the axial piston unit on the drive shaft or assembled parts, for
example, sensors or valves.
• For further storage conditions, see Table 7.
Check the axial piston unit monthly to ensure proper storage.