3000 W Ac&Hvdc Pm - Huawei ME60 Series Hardware Description

Hide thumbs Also See for ME60 Series:
Table of Contents

Advertisement

ME60
Hardware Description
Note the derating requirements of protection components when using protection components
such as fuses and circuit breakers. If the current of a PDF is less than 63 A, it cannot supply
power to the ME60-X16A. In this case, reconstruct power supply in the equipment room.
1.8.5.5 3000 W AC&HVDC PM
The external power is input to PMs through PEMs, the PMs convert AC power into regulated
DC power and output the power to the power supply backplane.
Overview
Table 1-72 Power attributes
Attribute
Description
BOM
Model
Table 1-73 Mapping products and versions
Product
ME60-X8A
ME60-X16A
Appearance
Figure 1-58 shows the appearance of a PM module.
Issue 01 (2018-05-07)
If the front-end PDF does not provide enough power inputs, configure a PDB that meets
the following requirements:
The current of each channel output by the DC PDB is not less than 63 A.
Double-channel backup is used.
The input current is not less than the sum of current of its connected output lines.
Description
3000W AC&HVDC Power Module
02310VMA
PHD-3000WA
Earliest Software Version
V800R008C10
V800R008C10
1 Hardware Description