120V Hard-Wire Connection - Napoleon CLEARion Elite NEFBD50HE Installation And Operation Manual

Hide thumbs Also See for CLEARion Elite NEFBD50HE:
Table of Contents

Advertisement

Available languages

Available languages

3.4

120V hard-wire connection

Remove the cover plate by removing the 3 screws.
A.
Set screws aside.
Add a strain relief and feed the supply wires through
B.
the 7/8" (22mm) hole from the terminal block. Use
minimum 14AWG/2.
Loosen the securing screws from the terminal block
C.
for the Green (G) wire. Insert Green (G) or bare copper
wire from power supply to the designated (G) slots in
the terminal block. Secure by tightening the screws on
the (G) slots.
Loosen the securing screws from the terminal block
D.
for the White (N) wire. Insert White (N) wire from power
supply to the designated (N) slots in the terminal
block. Secure by tightening the screws on the (N)
slots.
Loosen the securing screws from the terminal block
E.
for the Black (L1) wire. Insert Black (L1) wire from
power supply to the designated (L1) slots in the
terminal block. Secure by tightening the screws on the
(L1) slots.
Re-install cover plate.
F.
Black (L1)
White (N)
Red (L2)
Green (G)
note:
Leave enough wiring so that the appliance can be removed from the enclosure to access the hardwire
connections.
If 120V connections are wired incorrectly, the appliance will not function.
electrical information
Strain Relief
Inside
Outside
Appliance
Appliance
Black (L1)
White (N)
Green (G)
W415-2107 / F / 06.23.20
EN
120V
17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Clearion elite nefbd60he

Table of Contents