Furuno VR-7000 Instruction Manual page 21

Data extraction procedure
Hide thumbs Also See for VR-7000:
Table of Contents

Advertisement

3. Select each one of the following options from the drop-down list.
• For data extraction from the DCU:
• For data extraction from the fixed DRU:
• For data extraction from the float-free DRU: [Float DRU]*
• For data extraction from the save area:
(VR-7000S only)
*: Do not select during recording.
4. Confirm that the IP address ([Connect to IP]) shown below appears.
• [Long Term Device(LAN)]:
• [Fixed DRU]:
• [Float DRU]:
• [Long Term Device(Save Area)]:
(VR-7000S only)
5. If you selected [Long Term Device(Save Area)] at step 3, select the save area for data ex-
traction from [Save Area 1] to [Save Area 4].
6. Click the [Analyze Track] button.
Note: If one of the following messages appears, after clicking the [Analyze Track] button, refer
to the following table to rectify the error. If not rectified, contact your dealer.
Message
[ANALYZE] Could not analyze:
Long Term Device data. Reading
failed.
[CONN] [ANALYZE] Could not
analyze: Save area
[ANALYZE] Could not analyze:
Save-Area data. Reading failed.
7. Click the [Connect] button.
[Long Term Device(LAN)]
[Fixed DRU]*
[Long Term Device(Save Area)]
172.31.16.200 or 10.0.0.100
10.0.0.140
10.0.0.150
172.31.16.200 or 10.0.0.100
The Live Player V5 program version is not compatible with the
VDR program version. Check the VDR program version ([VDR
Version]) on the [System Monitor] window from the RAP, then
use an appropriate Live Player V5 version.
The Live Player V5 program version is older than the VDR pro-
gram version. Use the latest version of the Live Player V5.
The the VDR program version is older than Live Player V5 pro-
gram version. Use the Live Player V5 version 1.10.
17
5. DATA EXTRACTION/REPLAY
Remedy