Wall Control
To install the wall control, you must
first remove the faceplate and switch
assembly from the existing wall control,
if you have one.
Save the screws you removed from
the faceplate to use with the new
included faceplate.
Note: A power disconnect switch
should be installed in conjunction
with the wall control.
Rotary Switch
Terminal
Knob
Press the rotary switch terminal
into the hole in the faceplate as
shown with screw terminals facing
away from the light switch. Install
the knob onto the switch after it is
pressed into the faceplate.
MD520-01 • 10/06/14 • © Hunter Fan Company
Rotary Switch
Terminal
Capacitor
1
2
4
3
Connect the wires from the capacitor
to the rotary switch terminal as
follows:
Grey from the capacitor to
terminal 3. Tighten the set
screw.
Brown from the capacitor to
terminal 1. Tighten the set
screw.
Green from the capacitor to
terminal 4. Tighten the set
screw.
13
www.hunterfan.com.br
Rotary Switch
Rocker
Terminal
Switch
1
2
4
3
Attach a jumper wire (not included)
from terminal 2 of the rotary switch
to the center terminal of the rocker
switch. Tighten the set screws.