8. When timer sounds, lift basket out of oil. Place
on basket hanger (on splashback of fryer) to allow
draining of excess oil.
C. Basket-Lift Models
1. Fill fryer as described on page 4 - FILLING.
2. Set Power switch to the "On" position. "POWER
ON" light will be illuminated.
3. Set the Melt-Fry switch to "FRY."
4. Set thermostat to the desired frying temperature
(between 325°F and 335°F).
5. When the oil reaches the desired frying tempera-
ture, the "READY TO COOK" light will illuminate.
6. Fill basket(s) to proper level and place on upper
bar of lift rod(s).
7. Set timer(s) to desired cooking time. For program-
ming timers see page 8.
8. Push "T1," "T2" or "T3" buttons on timer(s).
Basket(s) will automatically lower into fryer vessel.
9. When cooking cycle is complete, an audible alarm
will sound and the basket(s) will raise automatically.
Allow oil to drain before removing baskets.
D. CPU Model
*See separate computer instructions or call
1-800-KEATING.

SHUTDOWN

A. BB, TS and Basket-Lift Models
1. Turn fryer Power switch to "OFF" position.
B. CPU Model
1. Set Main Power On/Off switch to the "OFF"
position.

DRAINING

ALWAYS SHUT THE FRYER OFF COMPLETELY BE-
FORE DRAINING. THE FRYER SHOULD BE DRAINED
ONLY UNDER THE SUPERVISION OF PROPERLY
TRAINED PERSONNEL. A DRAIN PIPE AND COV-
ERED CONTAINER SUITABLE FOR USE WITH HOT OIL
SHOULD BE USED TO ENSURE THE SAFETY OF THE
OPERATOR.
1. Operator should be outfi tted with proper attire
including:
– Oil and heat resistant gloves
– Oil and heat resistant apron
– Safety goggles
– Oil and heat resistant footwear
|
6
keatingofchicago.com
Figure 3
Operator in
Safety Gear
2. Turn off the fryer and open the door.
3. For front drain fryers, put approved container
under drain valve. For fryers with a central fi lter, slide
fi lter drawer in completely.
4. For front drain fryers, slowly turn handle forward
to avoid splashing. The drain valve will be completely
open after 1/4 turn.
5. For units with rear drain valves, slowly pull drain
valve operating handle straight out (unhook from
metal latch fi rst). See Safe & Easy operator's
manual for instructions on how to fi lter.
Figure 4
Front Drain Valve
Figure 5
Safe & Easy® Filter
DRAIN VALVE
Side view with
fi lter in battery
Side view with
fi lter under

Advertisement