You will need:
One standard fl at blade screwdriver
One accurate fryer thermometer
1. Set thermostat to desired frying temperature.
2. Allow thermostat to cycle three times.
2. Allow fryer to cycle three times.
3. Place an accurate thermometer in the oil.
4. If temperature of fryer is found to be more or
less than 15°F off, remove the thermostat knob.
There are (4) screws holding the dial plate in place.
Loosen the screws and reset the dial plate to
match the thermometer reading.
DO NOT ADJUST THE THERMOSTAT SET SCREW - IT
VOIDS ANY WARRANTY ON PART.
NOTE: Locate thermometer in same position for every
calibration. Position next to upper heating element is
recommended.

Thermostat Bulb Positioning

Keating's patented thermostat application is accurate
within ±7°F of the dial setting between 250°F and
350°F. This accuracy is attained only if the thermo-
stat bulb is placed properly against the top element
using element clamps. If the bulb is too far away from
the element, the fryer will overshoot.
Overshoot: The thermostat takes a long time to cycle
and then misses its preset temperature by 20°F -
40°F yielding a poor quality product.
ELECTRIC FRYER - SERIES 2006