Cleaning The Fan On The Left-Hand Side Of The Inverter Enclosure - SMA SUNNY TRIPOWER 15000TL Economic Excellence Installation Manual

Pv
Hide thumbs Also See for SUNNY TRIPOWER 15000TL Economic Excellence:
Table of Contents

Advertisement

SMA Solar Technology AG
9.2.3 Cleaning the Fan on the Left-Hand Side of the Inverter
Enclosure
1. Disconnect the inverter as described in Section 8 "Disconnecting the Inverter from Voltage
Sources" (page 55).
2. Turn the rotary fastener of the ventilation grid in the
direction of the arrow until the notch is in a vertical
position.
3. Remove the ventilation grid.
4. Wait for the fan to stop rotating.
5. Press the detents in towards the centre.
6. Remove the fan by pulling it slowly and carefully out sideways.
Installation Manual
Maintenance and Cleaning
STP15-20TLEE-IA-en-23