As-I Data; Abb Versions Hd5-B- Xxx - ABB HD5-B Series Original Instructions Manual

Three position enabling device with safe as-i slave
Table of Contents

Advertisement

AS-i data

The enabling device with integrated AS-i technology contains up to three slaves, depending on the
configuration.
The following bit description relates to functions that are generally possible, and is set out in detail in the
data sheet enclosed with the product (or available from ABB), depending on the configuration.
ABB versions HD5-B-xxx
(up to 12 enabling devices may be used on one AS-i cable)
Slave
I/O type
S-7.B.1.E
Safe code1
Safe code1
Address 29
Safe code2
upon
delivery
Safe code2
Output
Non safe
S-0.B.2.E
Safe code1
Safe code1
Address 30
upon
Safe code2
delivery
Safe code2
S-7.A.7.7
Input
Non safe
Address 31
upon
delivery
Output
Non safe
2CDC172107D0201
2019-09-06
Bit
Value
Description
D 0
emergency stop button
D 1
D 2
D 3
DO 0
0
red feedback LED in emergency stop button or below, OFF
1
red feedback LED in emergency stop button or below, ON
DO1
0
green feedback LED,
1
green feedback LED, activated
D 0
enabling button
D 1
D 2
D 3
DI 0
0
additional button 1,
1
additional button 1, actuated
DI 1
0
home position sensor, enabling device
1
home position sensor, enabling device hung up in holder
DI 2
0
additional button 3,
1
additional button 3, actuated
DI 3
0
additional button 4,
1
additional button 4, actuated
DO 0
0
green signal LED, OFF
1
green signal LED, ON
DO 1
0
red signal LED, OFF
1
red signal LED, ON
DO 2
0
assist light (flashlight), OFF
1
assist light (flashlight), ON
not
activated
not
actuated
not
actuated
not
actuated
25
not
hung up in holder
www.abb.com/lowvoltage
V2.6

Advertisement

Table of Contents
loading

Table of Contents