Pin
Signal
10
Service
required
11
End print
12
Media out
13
Ribbon out
14
Data ready
15
Verification
failed
PX940 Applicator Interface Installation Instructions
Type
Description
Output
Goes LOW during every status that keeps the
printer from printing:
• Printhead lifted
• Ribbon out
• Media out
• General print engine fault
• Front arm lifted
• Verifier calibration required
• Verifier calibration expired
• Exceed maximum barcodes
• Verifier hardware error
• Verifier failure action prompt
Output
Drives an applicator or other external device
requiring synchronization with the print
cycle. Choose between five types of output
signals:
• Mode 0: Applicator port is OFF.
• Mode 1: Asserted LOW only when media is
moving, otherwise de-asserted HIGH.
• Mode 2: Asserted HIGH only when media is
moving, otherwise de-asserted LOW.
• Mode3 (Default): Asserted LOW for 20ms
when label has finished printing and
positioned. Not asserted during continuous
printing.
• Mode 4: Asserted HIGH for 20 ms when label
has finished printing and positioned. Not
asserted during continuous printing.
Output
Goes LOW when the printer is out of media.
Output
Goes LOW when the printer is out of ribbon.
Output
Goes LOW when ready to print. De-asserted
HIGH when printing stops after the current
label.
Goes LOW when the printer encounters
Output
Verification failed error.
Goes HIGH when the error is cleared.