To defrost:
1. Turn unit off.
2. Remove all products from the interior and prop the
door in an open position (2 in. (5 cm) minimum).
3. Allow the frost to completely melt naturally. Clean the
interior and all removed components using a mild non-
abrasive detergent and warm water solution applied
with a soft sponge or non-abrasive cloth. NOTE: DO
NOT use any solvent-based or abrasive cleaners. They
will discolor or damage the interior.
4. Dampen a soft sponge or non-abrasive cloth in clean
water and wipe down the cabinet interior and removed
components to remove any detergent residue. Rinse the
sponge or cloth in clean water and repeat as necessary
until the cabinet and components are clean.
5. When the interior is dry, turn unit back on.
Condenser Cleaning
Interval - Every Three Months
To maintain operational efficiency, keep the front grille
free of dust and lint and clean the condenser every three
months. Depending on environmental conditions, more
or less frequent cleaning may be necessary.
WARNING
Disconnect electric power to the unit before
cleaning the condenser.
To remove and replace the grille for access to the
condenser fins, follow this procedure:
2
Figure 9
1. Disconnect electrical power to the unit.
2. Loosen two screws (Figure 9, 1) completely.
NOTE: Screws are held in the grille by o-ring retainers,
and will not come free of the grille.
3. Remove the grille.
WARNING
DO NOT touch the condenser fins. The condenser
fins are SHARP and can be easily damaged.
DO NOT use any type of cleaner on the condenser
unit.
4. Clean the condenser coil (Figure 9, 2) using a soft
5. Position the grille to align the mounting screws with
6. Secure, but do not over-tighten both grille screws.
7. Reconnect power to the unit.
Leveling
1. Use a level to check the levelness of the unit from front
1
ULIN_0203_A
2. If the unit is not level, adjust the feet on the corners of
3. Check the levelness after each adjustment and repeat
2115R, 2175R
CAUTION
brush with a "combing" action or vacuum cleaner. Do
not touch the condenser coil.
the holes in the cabinet.
1
Figure 10
to back and from side to side. Level should be placed
along top edge and side edge as shown (Figure 10).
Figure 11
the unit as necessary (Figure 11).
the previous steps until the unit is level.
ULIN_0193_A