Gima 32786 User Manual

Gima 32786 User Manual

Automatic wrist blood pressure monitor
Hide thumbs Also See for 32786:

Advertisement

Quick Links

PROFESSIONAL MEDICAL PRODUCTS
MISURATORE DI PRESSIONE SANGUIGNA AUTOMATICO-DA POLSO
AUTOMATIC WRIST BLOOD PRESSURE MONITOR
APPAREIL DE MESURE DE LA PRESSION ARTÉRIELLE AUTOMATIQUE-AU POIGNET
AUTOMATISCHER BLUTDRUCKMESSER FÜRS HANDGELENK
MEDIDOR DE PRESIÓN SANGUÍNEA AUTOMÁTICO-DE MUÑECA
MEDIDOR DA PRESSÃO SANGUÍNEA AUTOMÁTICO-DE PULSO
ΜΕΤΡΗΤΗΣ ΠΊΕΣΕΩΣ ΑΊΜΑΤΟΣ - ΑΥΤΟΜΑΤΟ-ΠΑΛΜOΥ
Manuale d'uso - User manual - Manuel de l'utilisateur
Gebrauchs- und instandhaltungsanleitung - Guía de uso
Guia para utilização - Οδηγίες χρήσης -
ATTENZIONE: Gli operatori devono leggere e capire
completamente questo manuale prima di utilizzare il prodotto.
ATTENTION: The operators must carefully read and completely
understand the present manual before using the product.
AVIS: Les opérateurs doivent lire et bien
comprendre ce manuel avant d'utiliser le produit.
ACHTUNG: Diese Anleitung muss vor dem Einsatz des Produkts
aufmerksam gelesen und vollständig verstanden werden.
ATENCIÓN: Los operadores tienen que leer y entender
completamente este manual antes de utilizar el producto.
ATENÇÃO: Os operadores devem ler e entender
completamente este manual antes de usar o produto.
ΠΡΟΣΟΧΗ: Οι χειριστές αυτού του προϊόντος πρέπει να διαβάσουν και να
καταλάβουν πλήρως τις οδηγίες του εγχειριδίου πριν από την χρήση του.
32786
Gima S.p.A.
Via Marconi, 1
20060 Gessate (MI) - Italy
Made in China
Gima S.p.A.
Via Marconi, 1 - 20060 Gessate (MI) Italy
gima@gimaitaly.com - export@gimaitaly.com
www.gimaitaly.com
0476

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 32786 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Gima 32786

  • Page 1 Gima S.p.A. Via Marconi, 1 - 20060 Gessate (MI) Italy gima@gimaitaly.com - export@gimaitaly.com www.gimaitaly.com PROFESSIONAL MEDICAL PRODUCTS MISURATORE DI PRESSIONE SANGUIGNA AUTOMATICO-DA POLSO AUTOMATIC WRIST BLOOD PRESSURE MONITOR APPAREIL DE MESURE DE LA PRESSION ARTÉRIELLE AUTOMATIQUE-AU POIGNET AUTOMATISCHER BLUTDRUCKMESSER FÜRS HANDGELENK MEDIDOR DE PRESIÓN SANGUÍNEA AUTOMÁTICO-DE MUÑECA...
  • Page 2: Safety Precautions

    ENGLISH SAFETY PRECAUTIONS - Babies, young children or individuals who cannot express their consent are not suitable to take blood pressure measurement. - Individuals with serious arteriosclerosis are not suitable to take blood pressure measurement. - Blood pressure readings may change in case of pregnancy. Pregnant women can consult their doctor before taking measurement.
  • Page 3 ENGLISH OVERVIEW Monitor Memory Power Recall (Start) (Up) Time Set Page Select (Down) Date Time Systolic Value User 1 Diastolic Value User 2 Pulse Value No. of Memory Low power warning Features • One Touch Operation • 2 User / 120 Total Memory •...
  • Page 4: Battery Installation

    ENGLISH PREPARATION Battery Installation 1. Squeeze slightly and pull to remove the battery cover. 2. Insert 2 AAA batteries with the polarities in correct direction. 3. Replace the battery cover. Press it lightly until the lock securely clicks into place. Note: Replace batteries when the battery indicator “...
  • Page 5: Applying The Wrist Cuff

    ENGLISH Applying the Wrist Cuff 1. Place your elbow on a table and palm facing upward, and wrap the arm cuff around the upper left arm. 2. Pull on the end of the cuff until it wraps securely around your upper wrist. Do not over tighten the cuff.
  • Page 6: Memory Functions

    ENGLISH MEMORY FUNCTIONS After measurement, the last set of measured values will be saved automatically after measurement when the unit is turned off by pressing “ ” button or by automatic power-off after 3 minutes. View Past Readings 1. Press the “p ”...
  • Page 7: Troubleshooting

    ENGLISH TROUBLESHOOTING Problem Cause Solution Have the batteries run Replace new batteries. No display when you out? press the Power / Are the battery polarities Re-align batteries in correct Start button. wrong? polarities. Check if the cuff is properly “Er P” displayed Fail to inflate.
  • Page 8: Specification

    ENGLISH SPECIFICATION Name Wrist Blood Pressure Monitor Model 32786 Measurement Oscillometric Measurement Range Pressure: 20-280 mmHg Pulse rate: 40/195 beats/min Accuracy Pressure: within +/- 3mmHg Pulse rate: within +/- 5% of reading Inflation Automatic inflation with pump Pressure Detection Semi-Conductor Power Supply 2x “AAA”...
  • Page 9 ENGLISH daily blood pressure values is very helpful for your doctor to diagnose. How to manage your Blood Pressure if it works unsuitable? If correct measurement is impossible even after checking the above-mentioned points, consult at the store where you have purchased the unit or the nearest dealer without touching the internal mechanism.
  • Page 10 The warranty is valid for 12 months from the date of supply of GIMA. During the period of validity of the warranty, GIMA will repair and/or replace free of charge all the defected parts due to production reasons.

Table of Contents