6.2 Oil Change

Frequency: see table 6.
If oil is changed according to the chart below, the life of the pump can be extended considerably.
Check
Change
Table 6 Oil change schedule
For practical reasons, it is better to change the oil when the pump is hot. The oil is then less viscous
and flows more easily out of the sump.
Turn the isolation switch off;
Depressurise the pump;
Place a pan to collect oil under the drain plug;
Remove the drain plug;
Recover the old oil and dispose of it as hazardous waste:
if there is any water in the oil, directly contact the supplier;
o
if the pump leaks oil, directly contact the supplier;
o
Remove any metal particles that have collected on the magnetic drain plug;
Replace and tighten the drain plug;
Remove the oil filler plug;
Fill the pump with oil:
Only use "Shell Omala S2 GX 220" oil or which is attributed in the product
o
specifications of the high pressure pump.
Check the oil level carefully when filling; too much oil is just as harmful as too little.
For pumps fitted with grease nipples on the piston seals:
Lubricate every 50 to 100 hours with HPF12 grease;
Use about 2 cm
3
of grease per nipple each time.