6. Maintenance

Routine maintenance and inspection is always necessary. Danfoss pumps require maintenance every
8,000 hours. Clean filters and check for oil or water leaks daily. For Hawk and Pratissoli pumps, the
following applies.
Every 500 hours
Check the oil level
Oil must only be replaced after the first 50 hours.
The set can be cleaned with a dry cloth; never use water on electrical parts. Do not use abrasive
cleaners.
Before working on the high-pressure system, make sure it has been depressurised and that the
isolating switch is turned off.

6.1 General

Frequency: weekly.
Turn the isolation switch off;
Depressurise the pump;
Check the oil level with the dipstick and/or use the oil sight glass:
the oil level should be at the mark;
o
for more on filling/changing oil, see 6.2;
o
Check that all connections are secure;
Check that all hoses are secure;
Check hoses for wear and damage:
replace if necessary;
o
Check connecting cables for wear and damage;
Check if all other nuts and bolts are tight;
Check the filter in the suction pipeline:
remove any foreign objects;
o
remove any dirt and scale deposits;
o
Check that the inlet pressure switch is working.
IBAN NL71 RABO 0340341610 · KvK Den Haag 27230471 · Btw-nummer NL8000.78.378.B01 · info@vanderendegroep.nl · www.vanderendegroep.nl
Every 1,000 hours
Replace the oil
Check or replace:
Check or replace:
Pagina 15 van 21
Van der Ende Groep · Aartsdijkweg 23, 2676 LE, Maasdijk · Telefoon 0174 515050
Valves
Valve seats
Valve springs
Valve guides
High Pressure gaskets
Low Pressure gaskets