Danfuss VLT 5000 Series Manual page 4

Frequency converter
Table of Contents

Advertisement

I Transportation and unpacking
To lessen the possibility of damage it is recom-
mended that the crated VLT frequency converter is
located as close to the final installation site as possi-
ble before uncrating.
Door and ceiling clearances must be considered
when moving and installing the VLT frequency con-
verter. See below table for the crate dimensions:
Dimensions [mm]:
H
IP 00
2096
IP 20 / 54
2324
Weight [kg]:
VLT
VLT
5300/
5350/
6350
6400
IP 00
548
583
IP 20
654
689
IP 54
664
699
A qualified person with a forklift or other similar lifting
device will be needed to remove the VLT frequency
converter from the crate.
To open the crate:
• Remove the metal locking tabs that secure the
top panel of the crate, this will give access to the
lifting rings on the top of the VLT frequency con-
verter.
4
W
D
1219
699
1321
724
VLT
VLT
5450/
5500/
6500
6550
628
653
734
759
744
769
®
VLT
5000/6000 Series
• On IP 00 versions remove the supporting brace
bolted to the lifting rings.
• A forklift or similar lifting device should be used at
this time to ensure the stability of the VLT fre-
quency converter while the rest of the crate is
removed. Position the lifting device to the front
side of the crate.
• The VLT frequency converter should be lifted us-
ing a spreader bar or other similar lifting device.
Lift the VLT frequency converter slightly, using all
four lifting rings, distributing the weight as evenly
as possible.
MG.56.A1.02 - VLT is a registered Danfoss trade mark