  • Page 1 USER MANUAL SUNDAY 200 SOL...
  • Page 2: Table Of Contents

    CONTENTS Precautions page 4 General safety information “ Control panel “ Start-up “ Shutdown “ Warning LEDs and errors “ Cleaning “ Maintenance “ Useful information “ The following symbols are used in this manual: = Identifies actions that require caution and ade- quate preparation.
  • Page 3 Dear Customer, Thank you for choosing a THERMITAL boiler. You have purchased a modern, high efficiency, qual- ity product that will give you an excellent level of comfort as well as silent, safe service for many years to come. Arrange for your boiler to be serviced regularly by Technical Assistance Service.
  • Page 4: Precautions

    The boiler must only be used for the purpose spec- ified by THERMITAL and for which it is designed. that the installation has been com- pleted to the highest standards in compliance with the...
  • Page 5: Control Panel

    CONTROL PANEL THE MAIN CONTROL PANEL 40 60 80 1 Storage cylinder temperature gauge Displays domestic hot water temperature. 2 Boiler pressure gauge Displays the pressure in the central heating circuit. Å Storage cylinder temperature selector (NOT USED) The temperature of the domestic hot water is preset to 44°C in the factory. The thermostatic mixer valve has to be adjusted to change this value (see page 9).
  • Page 6 SOLAR CONTROLLER Function selector Enter button Parameter selector Escape button Function selector Storage cylinder top temperature sensor No function selected / Stand-by. (The display - The display reads out the temperature currently shows that the system is switched on but in stand-by mode) measured by storage cylinder top temperature sensor F3.
  • Page 7: Start-Up

    START-UP Have THERMITAL’s Technical Assistance Service start-up your boiler for the first time. Once this has been done, the boiler can be left to function automatically. Under certain circumstances, such as after long periods of disuse, the user may need to re-start it without involving the THERMITAL’s Technical Assistance Service. Before doing so, perform the following checks and operations.
  • Page 8 SUMMER ( ): With the function selector set to Summer, Ç the boiler functions only in domestic hot water mode. The temperature gauge (1) shows the temperature of the hot water inside the storage cylinder. To ensure correct functioning, set the room temper- 40 60 80 ature thermostat to its minimum setting.
  • Page 9 SETTING DOMESTIC HOT WATER TEMPERATURE Domestic hot water temperature is preset to 44°C in the Domestic hot water from the factory. 40 60 80 SOLAR STORAGE CYLINDER Adjust the thermostatic mixer valve to change this value. user The following table shows the hot water temperature val- points ues for the different mixer valve knob positions.
  • Page 10 SOLAR CONTROLLER The first time you switch on the boiler, you will need to set time and day. To do so, proceed as follows. - Turn the function selector (3) to " " - Turn the parameter selector (4) until the "Clock" menu appears.
  • Page 11: Shutdown

    RESET FUNCTION To reset the boiler, turn the function selector to “ É ”, then return it to its previous position and check that the red LED goes out. Provided correct functioning conditions have been restored, the boiler restarts automatically. As soon 40 60 80 as the burner ignites the green LED lights and the digital display will read out current operating temperature.
  • Page 12: Warning Leds And Errors

    If the boiler is not going to be used for an extended peri- od of time, proceed as follows to prepare it for shutdown. - Turn the function selector to OFF/RESET. - Turn the mains power switch OFF. - Close the fuel shut-off cock and the central heating and DHW circuit shut-off cocks.
  • Page 13 Dealing with error AL41 Check the pressure on the control panel pressure gauge. If it is below 0.5 bar, proceed as follows. - Turn the function selector to “ ” É - Remove the top front panel from the boiler by pulling it forwards.
  • Page 14: Cleaning

    PROFESSIONALLY QUALIFIED HEATING ENGINEERS UNDERTAKE PERIODIC MAINTENANCE COMBUSTION EFFICIENCY MEASUREMENTS. THERMITAL’s Technical Assistance Service is qualified to satisfy these legal requirements and can also provide useful information on MAINTENANCE PROGRAMMES designed to guarantee: - greater safety - compliance with applicable legislation - freedom from the risk of fines in the event of spot checks.
  • Page 15: Useful Information

    USEFUL INFORMATION Seller: Installer: ....................................................................................................................Address Address ......................................................Tel. Tel............................................................Technical Assistance Service: ............................................Address ............................Tel............................... Date Work done Fuel oil supplier: ....................................................Address ............................Tel............................... Date Quantity supplied Date Quantity supplied Date...
  • Page 16 RIELLO S.p.A. Via Ing. Pilade Riello, 7 37045 - Legnago (VR) www.thermital.it As part of the company’s ongoing commitment to perfecting its range of products, the appearance, dimensions, technical data, equipment and accessories may be subject to variation.