ACQUAHOME 32 boiler. B - 32 BS Please accept our renewed thanks for your purchase. Thermital CONFORMITY boilers conform to the following di- ACQUAHOME 32 B - 32 BS rectives:...
GENERAL INFORMATION Precautions The operation of any appliance that uses fuel, electrical power and water demands that a number of fundamental safety General Safety Information precautions be respected: Do not allow children or infirm persons to operate the Check that the product is complete, undamaged system unsupervised.
(100°C). The sensor used to monitor this tem- chamber. perature is located on the body of the heat exchanger; Model ACQUAHOME 32 BS (unlike model ACQUAHOME 32 B ) - Sensors that measure the temperature of the boiler and has a sealed chamber.
Control panel ACQUAHOME 32 B - 32 BS Function selector Burner reset Electronic control unit Boiler pressure gauge Displays the pressure in the central heating circuit Fuse holder Holds the protective fuse 6.3 A-T Indicator showing a burner lockout for a tripped safety thermostat (red) Lights to show that the safety thermostat has tripped Burner lockout indicator (red) Lights to show that the burner locked out...
Electronic control unit The electronic controller provides the interface by means of which the installer and user can set and change functioning parameters and view boiler status. The electronic controller lets you: - Change the functioning mode; - View the temperature of the boiler and storage cylinder; - Change the boiler and storage cylinder parameters (password required);...
Navigation scheme Displaying and changing storage cylinder settings Displaying and changing boiler settings Displaying hours remaining to the next service ENGLISH...
Start-up Once you have completed all the checks listed above, proceed as follows to start up the boiler for the first time: Putting into service - Turn the boiler’s mains power switch ON Have the Technical Assistance Service start up your ACQUAHOME 32 B - 32 BS boiler for the first time.
Ignition failure Resetting the burner and safety thermostat If any ignition errors or malfunctions occur, the burner enters To restore normal startup conditions, open the cover of the “LOCKOUT”. This is shown by the red button light on the control panel and turn the function selector to "Reset burner"...
Menu settings CHANGING THE FUNCTIONING MODE You can only change the boiler’s functioning mode when the display is reading out either boiler or storage cylinder temperature. Press the "mode key" repeatedly to scroll to the TEMPERATURE DISPLAY required functioning mode. The default setting is "Winter". - In stand-by mode (with the indicator lit) the boiler Storage cylinder temperature display...
Page 14
Press the key to confirm the setpoint and return to the storage If you press the key while the boiler temperature is cylinder temperature display. The indicator stops flashing. displayed, the indicator starts to flash and the boiler's current setpoint is shown on the three digit display. The default value is 75°C.
Temporary shutdown Preparing for extended periods of disuse To switch the boiler off for short periods with outdoor If the boiler is not going to be used for an extended period of temperature ABOVE ZERO: time, proceed as follows to prepare it for shut-down - Open the control panel access door;...
Cleaning and servicing the boiler Please remember that PERSON RESPONSIBLE SYSTEM MANAGEMENT MUST ENSURE THAT PROFESSIONALLY QUALIFIED HEATING ENGINEERS UNDERTAKE PERIODIC MAINTENANCE AND COMBUSTION EFFICIENCY MEASUREMENTS. ’s Technical Assistance Centre is qualified to satisfy these legal requirements and can also provide useful information on MAINTENANCE PROGRAMMES designed to guarantee: - greater safety...
Page 17
SYSTEM ERRORS AND ALARMS Alarm Description This message on the three digit display indicates an active burner lockout alarm. The indicator shows steady light. This message on the three digit display indicates an active safety temperature alarm (safety thermostat tripped). The indicator shows steady light.
Troubleshooting FAULT CAUSE SOLUTION - Contact your local Technical Fumes escaping into the air There is a smell of fumes Assistance Centre - Contact your local Technical Air in the circuit Assistance Centre The generator is at temperature but the heating system is cold - Contact your local...
Page 20
RIELLO S.p.A. Via Ing. Pilade Riello, 7 37045 - Legnago (VR) www.thermital.it The manufacturer strives to continuously improve all products. Appearance, dimensions, technical specifications, standard equipment and accessories are therefore liable to modification without notice.