EHFZ03S18DJ3V
Daikin Altherma 3 R F
4P596825-1 – 2019.10
Possible actions per control
Control
Room temperature
Main leaving water
temperature
Additional leaving
water temperature
DHW tank temperature Program when to heat up the DHW tank. The possible
Booster heater
allowance
Quiet mode
(Only for field
supplied domestic hot
water pump for
secondary return)
Domestic hot water
pump
(a)
Start heating up until the desired setpoint (Comfort/Eco) is reached.
(b)
Stop heating, even if the desired temperature is not reached yet; example: if
electric tariffs are higher during the day, you can program a stop at 06:00.
To select which schedule you currently want to use
1 Go to [5]:
> Select schedules.
2 Select for which control you want to use a schedule. Example: [5.1] Room
temperature.
3 Select for which operation mode you want to use a schedule. Example: [5.1.1]
Heating .
4 Select a predefined or user‑defined schedule and press
To program a schedule
1 Go to [7.3]:
> User settings > Set schedules.
2 Open an empty, predefined or user‑defined schedule.
3 Change it.
4 Save it.
Possible actions
Program when to heat up or cool down a space:
Comfort (preset value)
Eco (preset value)
[Custom temperature]
Program when the additional leaving water temperature
is turned ON and OFF.
actions depend on an installer setting.
Possible actions 1:
Storage comfort (preset value)
Storage eco (preset value)
(b)
Storage stop
Program when the booster heater can operate.
Example: Only allow the booster heater to operate
during the night.
Program when the unit has to use which quiet mode
level:
Level 1
Level 2
Level 3
OFF
Program when the domestic hot water pump is turned
ON and OFF.
3
Operation
|
(a)
(a)
.
User reference guide