Daikin Altherma 3 R F User Reference Manual page 24

Hide thumbs Also See for Altherma 3 R F:
Table of Contents

Advertisement

3
|
Operation
To adjust/overrule the leaving water temperature (NOT linked to room temperature setpoint)
To adjust the leaving water temperature (additional)
To adjust/overrule the leaving water temperature (linked to room temperature setpoint)
User reference guide
24
INFORMATION
To see if the leaving water temperature setpoint is linked to the room temperature
setpoint, see
"3.4.3 Determining which temperature control you are
To adjust the leaving water temperature (main)
1 Go to the main leaving water temperature home page (LWT main).
2 Press
or
to adjust. Example:
INFORMATION
In case of weather dependency, an offset value can be modified.
1 Go to the additional leaving water temperature home page (LWT add).
2 Press
or
to adjust. Example:
INFORMATION
In case of weather dependency, an offset value can be modified.
INFORMATION
To see if the leaving water temperature setpoint is linked to the room temperature
setpoint, see
"3.4.3 Determining which temperature control you are
To set leaving water temperature preset values (main)
INFORMATION
You cannot adjust/overrule the leaving water temperature (main) for room
thermostat control with linked leaving water temperatures. However if necessary,
you can adjust the desired leaving water temperature (main) by adjusting preset
values.
INFORMATION
Adjusting the leaving water temperature is permanent unless the leaving water
temperature is according to a schedule. In that case the overruling is valid until the
next scheduled action.
1 Go to [7.4.2]:
> User settings > Preset values > LWT main.
2 Set the Preset values according to following graph.
Example: Room thermostat comfort temperature will correspond with leaving
water comfort temperature.
35°C 37°C
45°C 47°C
4
using" [
 17].
4
using" [
 17].
EHFZ03S18DJ3V
Daikin Altherma 3 R F
4P596825-1 – 2019.10