Tig Welding (2T Operation) - SanRex SANMIG 200MF Operator's Manual

Inverter dc mig welder
Table of Contents

Advertisement

t6~t7: Post flow time, adjustment range of post flow time: 0.1~10.0S;
t7:
Electromagnetic valve is closed and stop argon flowing. Welding is finished.
§4.3.2 TIG welding (2T operation)
TIG short welding(2T) :
I(A)
Welding current Is
The setting base
current Ib
Press and hold the welding
gun switch
Introduction:
0:
Press and hold the gun switch, Electromagnetic gas valve is turned on. The
shielding gas starts to flow;
0~t1: Pre flow time, adjustment range of pre flow time :0.1~1.0S;
t1~t2: Striking success, the output current slopes up to the setting current from minimum
current (5A);
t2~t3: During the whole welding process, the gun switch is pressed and held without
releasing;
t3:
Loosen the gun switch, the output current slopes down;
t3~t4: The output current slopes down to minimum current (5A), stop arc; adjustment
range of down slope time: 0~5S;
t4~t5: Post flow time, adjustment range of post flow time: 0.1~10.0S;
t5:
Electromagnetic valve is closed and stop argon flowing. Welding is finished.
Short circuit protect function:
○ 1 TIG /DC/LIFT:If the tungesten electrode touches the workpiece when welding, the current
MAINTENANCE &TROUBLESHOOTING
Arc is
ignited
0
t1
t2
26
Loosen the
welding gun
switch
Arc is
turned off
t3
t4
t5
t(s)

Advertisement

Table of Contents
loading

Table of Contents