Dc Hf Tig & Lift Tig Welding - SanRex SANARG 160P Operator's Manual

Dc inverter arc welder
Table of Contents

Advertisement

6.2
DC HF TIG & LIFT TIG WELDING
• Connect work lead to positive terminal
• Connect TIG torch to negative terminal
• Switch machine on
• Set WELD current.
• Connect remote control device. A remote control device is required for use during LIFT TIG and HF
TIG operation. See section 4.3, "8-PIN REMOTE CONTROL RECEPTACLE", for complete details
of the remote device.
Use the Scroll Buttons to move to the parameter to be set. The LED will show which function is being
adjusted on the weld sequence graph. Use the control knob to adjust each parameter.
• Set PRE-FLOW time
• Set HOT START current
• Set POST-FLOW time
• Set WELD current
• Set POST-FLOW time
Slope Mode Parameters if required
• Set INTIAL CUR current
• Set UP SLOPE time
• Set (WELD) PEAK CUR current
• Set BASE current
• Set DOWN SLOPE time
• Set CRATER CUR current
Pulse Mode parameters if required
• Set PULSE WIDTH % for PEAK CURRENT
• Set PEAK CURRENT
• Set PULSE FREQ
Commence welding
52

Advertisement

Table of Contents
loading

Table of Contents