To reset the product
The ON/OFF switch can be used as a reset switch if the
inverter releases. Reset the product when the indicator
inverter to the grinding motor (A) is red.
A
1. Turn the STOP/RUN switch (B) counterclockwise to
0 to make sure that the grinding head is off.
2. Turn the ON/OFF switch to the arrow position (C) to
reset the product. The indicator for the inverter to the
grinding motor is green when the fault is reset.
3. Turn the STOP/RUN switch on the control panel
clockwise to start the grinding head again.
Weights
The product has 1 weight on each side of the product. If
the product is heavy to operate, adjust the weights to
change the pressure on the grinding head. The weights
must be adjusted to the same position on the right and
the left side. The weights has 2 positions:
Position 1: Maximum pressure on the grinding head.
This position increases the operation effect. This
position is also used when you set the product in
transport position.
1211 - 003 - 22.01.2020
B
C
Position 2: Minimum pressure on the grinding head.
This position is also used when you tilt the product to
servicing position.
To assemble and disassemble the weights
The product has 1 weight on each side of the product.
Do the procedure that follows on each weight.
1. Install the weight holder and tighten the 3 screws.
2. Put the weight on the cylinder on the weight holder.