Download Print this page

Profelmnet 3029 Quick Start Manual page 2

For rolling shutters up to 1200watt

Advertisement

Functions and connections
RED indication light goes ON (after a small delay). Leave it and during the next
3 seconds, press the desired transmitter channel button until the RED
indication light blinks and goes OFF. The new transmitter is saved. Follow the
same procedure to program more (up to 300) new transmitters.
Working time:
Adjustable from 1-180S. While the gate is fully closed, press and keep the
TIME button of the control panel pressed until the gate goes to fully open
position. Then leave it. The working time is saved.
Adding a new transmitter remotely:
The motor is fully closed or open. Press a working transmitter button (already
in memory) to start the motor working and hold it pressed until the motor
stops. When it stops, leave it and press the new transmitter button
immediately. The new transmitter is saved. Repeat steps to program more
transmitters remotely. When the memory is full (300 transmitters) you cannot
add more new transmitters.
Pedestrian function:
When the pedestrian traverses the gate, the gate will open for a while and then
automatically will close. Photocells need to be installed. The time of closing is
the same with the second time of A/C.
Power supply 230V:
Supply the control panel with
230Vac.Check that the yellow
indication light is ON. Press the
button of the transmitter and
check the red indication light is
ON (receiver).
Clear memory:
The first step is to clear the
control panel memory. Press the
button CODE of the control panel
and the RED indication light goes
ON after a while. Keep it pressed
until the RED indication light goes
OFF. The memory is now clear.
Adding a new transmitter
with the control panel
button:
Press the CODE button and the
Ag.Dimitriou 286A ,173 42 Agios Dimitrios
Τηλ. Κέντρο: 210 9850 244, Fax: 210 9823 264
Photo-cell connection:
Connect the photocell contact and power supply 24VAC according to the
diagram in the right. When you finish, put the program dipswitch 5 in ON
position.
Photocell operation:
When
the door closes and the photocell
beam is cut-off, the door stops
immediately
and
automatically
activates the open function. If the
photocell beam is cut-off, the door
never closes.
Blinker light function:
The blinker light gives a permanent voltage of 230V / 10W, connects to
terminals 1 & 3 and operates as long as the gate is moving. If you want to
flashes for more time, eg 100 seconds, then program 100-second for the
working time of the control panel.
Adjusting the auto close time:
There is a double counter in the A/C function. The first one is 120 seconds
and is applied when the door stops after an open function. During this
counting time of 120 sec., if the photocell beam is disturbed, then after the
beam is free, the A/C counting time becomes 10 sec. until the fully closed
position. In this control panel, the second counting time of 10 sec., can be
regulated. Press the TIME button, keep it pressed and within 1 sec. , press
the CODE button.
The red indicating light starts flashing, indicating the
seconds of the counter. The time of the counter is from 1-120 seconds. Keep
it pressed for the time you wish to give in A/C and pedestrian function. The
dipswitch 3 needs to be ON.
Indication light LED:
There are indication LED lights that displays the different functions of the
control panel for the photocells.
Reset the automation
:
Case of malfunction, please remove the power supply (230Vac) for 10
seconds, reconnect and recheck.
Compatible transmitters
:
Based on the model you have, select the appropriate transmitter.
www.profelmnet.com

Advertisement

loading