Dip-Switches; Asic Interface Configuration ( S1 ) - Profichip VPC3+S Manual

Evaluation kit
Hide thumbs Also See for VPC3+S:
Table of Contents

Advertisement

3.4

DIP-Switches

Changing the settings of any DIP-switch or jumper is permitted in power-off
state only. Modifying these settings in power-on state will possibly lead to an
undefined behavior and cause permanent damages.

3.4.1 ASIC Interface Configuration ( S1 )

Bits 1 to 3 of the DIP-switch S1 select the interface mode of the PROFIBUS
ASIC. If the VPC3+ PROFIBUS Board is used together with the
AT89C5132 controller board S1.4 needs to be set to OFF. It needs to be
set to ON if a 3
Board is directly connected to the customer electronic.
Bit
1
2
3
4
Notes:
1) : the corresponding VPC3+ pin is named MOT/XINT
2) : should be set to ON if not used in combination with the AT89C5132 controller board
Figure 3-9: Configuration of the Interface Mode
VPC3+S Evaluation Kit
Copyright © profichip GmbH 2009