1.7
1.8
APPENDIX B - SECTION 1
START-UP ERRORS (Cont' d". )
- DPU Config Processing (Cont'd.)
To bypass the error, follow the restart procedure at 1.8 until the DPU
completes start-up with the prompt "9?".
Then enter the "CBLD" function to
correct the indicated errors.
Reboot the DPU after the "CBLD" command.
GENERAL INFORMATION
The DPU config is contained on two separate files within the SMTCS (System
Maintenance and Test Control Software) diskette:
- System Attributes and non-comm directives are on the file CLM USER, which
is fixed and not accessible by the DPU user.
CLMgUSER contains diskette,
and local terminal configuration information.
COMM directives (MLCP connections) are on the file CLM SITE, which is site
dependent and accessible by the DPU user via the "CBLD" command.
CLM;SITE
contains remote,
system console, and unit connection (CPUXX, SCUXX)
configuration information.
The Config Load Manager (CLM) processes the DPU config sequentially,
starting with CLM;USER, then CLM;SITE.
CONFIG COMMAND RESTART PROCEDURE
Config errors (OBXX and 13XX) may be bypassed and processing continued by
clearing R1 (Dl on DPU Maintenance Panel) and resuming:
On the DPU Maintenance Panel:
— Depress
STEP
SELECT.
." Key in "D1" to select register 1.
~ Depress CHANGE.
- Key in "0000" to clear R1.
~ Depress
RUN.
,
EXECUTE
to resume processing.
If additional errors are detected (as is genenally the case), repeat the
above procedure until all config errors are bypassed.
Start-up is complete
with the prompt "93" on the local VIP.
B-3
'
REV. 2