Off-Season Storage

To prevent battery damage during extended periods of non-use,
the following basic battery maintenance items must be
performed:
• Remove the battery from the machine and wash the
case and battery tray with a mild solution of baking
soda and water. Rinse with lots of fresh water after
cleaning.
• Using a wire brush or knife, remove any corrosion from
the cables and terminals.
• Charge at a rate no greater than 1/10 of the battery's
amp/hr capacity.
• Store the battery either in the machine with the cables
disconnected, or store in a cool place.
NOTE: Stored batteries lose their charge at the rate
of 1% per day. Recharge to full capacity every 30 to
60 days during a non-use period. If the battery is
stored during the winter months, electrolyte will
freeze at higher temperatures as the battery
discharges. The chart below indicates freezing
points by specific gravity.
Electrolyte Freezing Points
Specific Gravity
of Electrolyte
1.265
1.225
1.200
1.150
1.100
1.050
10.38
Freezing Point
-75° F
-35° F
-17° F
+5° F
+18° F
+27° F

Battery Charging

If battery voltage is 12.8 V or less, the battery may need
recharging. When using an automatic charger, refer to the
charger manufacturer's instructions for recharging. When using
a constant current charger, use the following guidelines for
recharging.
NOTE: Always verify battery condition before and 1-
2 hours after the end of charging.
An overheated battery could explode, causing
severe injury or death. Always watch charging
times carefully. Stop charging if the battery
becomes very warm to the touch.
Allow it to cool before resuming charging.
Battery Charging Reference Table
State of
Voltage
Charge
None, check
voltage at 3 mos.
100%
12.8-13 V
after manufacture
date
May need slight
75-100% 12.5-12.8 V
charge
50-75%
12.0-12.5 V Needs Charge
25-50%
11.5-12.0 V
Needs Charge
0-25%
11.5 V or less Needs Charge
To avoid the possibility of sparks and explosion,
connect positive (red) cable first and negative
(black) cable last.
WARNING
Action
Charge Time
None Required
3-6 hours
5-11 hours
At least 13
hours, verify
state of charge
At least 20 hours