Chengdu Ebyte Electronic Technology Co.,Ltd.
Description:Restart to take effect, save when power off,Set according to the UUID length, follow the little-endian pattern, the
high level is followed
For example, set the two-byte UUID to"FFF2":41 54 2B 55 55 49 44 43 48 41 52 32 3D F2FF
For example, the sixteen-byte UUID is"11223344556677889900AABBCCDDEEF2":
41 54 2B 55 55 49 44 53 56 52 3D F2EEDDCCBBAA00998877665544332211
6.32 Query, enable, disable serial port delay
Command
Query:AT+DELAYDATA?
Setting:AT+DELAYDATA=[para]
Description: It takes effect immediately, save when power off
6.33 Restart command
Command
AT+RESET
Description: It takes effect immediately, equivalent to power off and restart
6.34 Restore Factory
Command
AT+RESTORE
Description: It takes effect immediately, the parameters set by users are always changed to the parameters at the factory and
restarted
6.35 Authenticate configuration over air password
Command
Authentication:AT+AUTH =[para]
Description:
1. Password cannot be changed before successful authentication.
2. This command is only used in configuration over air, other methods have no practical meaning.
Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co.,Ltd.
3-26
Response
+OK=[para]
+OK:Success
+ERR=[NUM]:Error
Response
+OK
Response
+OK
+OK:Success
+ERR=[NUM]:Error
para:0、1
0:Disabled
1: Enabled
No
No
Response
para:6-byte password
E104-BT51 User Manual
Parameter
Parameter
Parameter