Siemens SIMATIC ET 200L Manual
Siemens SIMATIC ET 200L Manual

Siemens SIMATIC ET 200L Manual

Distributed i/o device
Hide thumbs Also See for SIMATIC ET 200L:
Table of Contents

Advertisement

DATASHEET
SIEMENS
6ES7132-1BH00-0XB0
OTHER SYMBOLS:
RGB ELEKTRONIKA AGACIAK CIACIEK
SPÓŁKA JAWNA
Jana Dlugosza 2-6 Street
51-162 Wrocław
Poland
biuro@rgbelektronika.pl
+48 71 325 15 05
www.rgbautomatyka.pl
www.rgbelektronika.pl
www.rgbelektronika.pl
www.rgbautomatyka.pl

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SIMATIC ET 200L and is the answer not in the manual?

Questions and answers

Summary of Contents for Siemens SIMATIC ET 200L

  • Page 1 DATASHEET SIEMENS 6ES7132-1BH00-0XB0 OTHER SYMBOLS: RGB ELEKTRONIKA AGACIAK CIACIEK SPÓŁKA JAWNA Jana Dlugosza 2-6 Street 51-162 Wrocław www.rgbelektronika.pl Poland biuro@rgbelektronika.pl +48 71 325 15 05 www.rgbautomatyka.pl www.rgbautomatyka.pl www.rgbelektronika.pl...
  • Page 2 YOUR PARTNER IN MAINTENANCE Repair this product with RGB ELEKTRONIKA ORDER A DIAGNOSIS LINEAR ENCODERS SYSTEMS INDUSTRIAL COMPUTERS ENCODERS CONTROLS SERVO AMPLIFIERS MOTORS MACHINES OUR SERVICES POWER SUPPLIERS OPERATOR SERVO PANELS DRIVERS At our premises in Wrocław, we have a fully equipped servicing facility. Here we perform all the repair works and test each later sold unit.
  • Page 3 SIMATIC Preface, Contents ET 200L Product Overview Distributed I/O Device Installation Manual Wiring Commissioning Diagnostics General Technical Data Terminal Blocks and Supplemen- tary Terminals – Technical Data ET 200L Electronics Blocks – Technical Data Order Numbers Type and Device Master Files Glossary, Index Edition 10/2005 EWA-4NEB 780600902-05...
  • Page 4 Trademarks All names identified by ® are registered trademarks of the Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
  • Page 5: Preface

    Preface Purpose of the The information provided in this manual enables you to operate the distrib- Manual uted I/O. Basic knowledge To understand the manual, you require general experience in the field of au- required tomation engineering. Scope of this This manual is applicable to the components of the ET 200L distributed I/O manual system.
  • Page 6 The online catalog and ordering system are available at: http://mall.ad.siemens.com Training center Siemens offers various courses to get you started with the ET 200L distrib- uted I/O and the SIMATIC S7 automation system. Please contact your re- gional Training Center, or the central Training Center in D-90327 Nurem- berg.
  • Page 7: Table Of Contents

    Contents Preface ..............Product Overview .
  • Page 8 Contents Terminal Blocks and Supplementary Terminals – Technical Data ... Terminal Block TB 16L – 6ES7 193-1CH00-0XA0, 6ES7 193-1CH10-0XA0 ......... . Terminal Block TB 32L –...
  • Page 9 Contents Figures A Typical PROFIBUS-DP Installation ....... View of the ET 200L Distributed I/O Device .
  • Page 10 Contents Tables General Components for the ET 200L ......Components of the ET 200L Distributed I/O Device .
  • Page 11: Product Overview

    Product Overview In This Chapter The product overview provides information about The role of the ET 200L distributed I/O device within the ET 200 distrib- uted I/O system. The components which make up the ET 200L distributed I/O device. Contents of the Section Subject Page...
  • Page 12: What Is The Et 200 Distributed I/O System

    Product Overview What Is the ET 200 Distributed I/O System? What Is the When a system is installed, the input/output modules are normally installed ET 200? centrally in the programmable logic controller. If inputs and outputs are made at long distances from the programmable logic controller, there may be long runs of cabling which are not immediately com- prehensible, and electromagnetic interference may impair reliability.
  • Page 13: What Is The Et 200L Distributed I/O Device

    Product Overview What Is the ET 200L Distributed I/O Device? Definition The ET 200L distributed I/O device is a DP slave within the ET 200 distrib- uted I/O system, its degree of protection being IP 20. Applications Owing to its compact and flat design, the ET 200L distributed I/O device is particularly suitable for applications in which space is at a premium.
  • Page 14: General Components For The Et 200L

    Product Overview General Compo- A range of components are available for setting up the ET 200L. You will nents for the find the components that you require for all versions of the ET 200L in ET 200L Table 1-1. You will find other components in Section 1.2.1. Table 1-1 General Components for the ET 200L Component...
  • Page 15 Product Overview Terminal Block The terminal block (TB) is used for mounting the electronics block (EB). It contains the wiring so that if the electronics block is replaced, leads do not have to be loosened. The terminal block is characterized by the following: It can be pre-wired before the electronics block is mounted.
  • Page 16: What Is The Et 200L Block I/O Device

    Product Overview 1.2.1 What Is the ET 200L Block I/O Device? Features of the Figure 1-2 shows you a view of the ET 200L distributed I/O device. It con- ET 200L sists of a terminal block and an electronics block. Electronics block Terminal block Figure 1-2...
  • Page 17: Components Of The Et 200L Distributed I/O Device

    Product Overview ET 200L Compo- A whole range of components is available for installing and commissioning nents the ET 200L. The most important components and their functions are listed in Table 1-2: Table 1-2 Components of the ET 200L Distributed I/O Device Component Function Illustration...
  • Page 18 Product Overview ET 200L Distributed I/O Device EWA-4NEB 780600902-05...
  • Page 19: Installation

    Installation Introduction The ET 200L distributed I/O device has been designed for simple installation and wiring. To this end, the label of the ET 200L distributed I/O device has been made self-explanatory. In this chapter, you will find additional information on installing and wiring the ET 200L distributed I/O device.
  • Page 20: Installing The Et 200L Tb 16L/Tb 32L Terminal Block And Supplementary Terminal

    Installation Installing the ET 200L TB 16L/TB 32L Terminal Block and Supplementary Terminal Introduction In this section, we describe how you install the terminal block and the sup- plementary terminal. Requirements Install the terminal block on a rail. You install the ET 200L distributed I/O device on a rail conforming with EN 50022 (35 7.5 or 35 15).
  • Page 21: Installing The Terminal Block

    Installation Installing the Ter- Install the terminal block in the following order: minal Block 1. Mount the terminal block on the rail. 2. Tilt the terminal block backwards until you hear both the safety bolts en- gage. You can now wire the terminal block (refer to Chapter 3) before you install the electronics block.
  • Page 22: Disassembling The Terminal Block

    Installation Disassembling the Remove the terminal block in the following order (refer also to Figure 2-2): Terminal Block 1. Turn off the power supply. 2. Remove the electronics block. – Remove the bus connector. – Loosen the fixing screw. – Tilt the electronics block forwards. 3.
  • Page 23: Installing And Disassembling The Et 200L Electronics Block

    Installation Installing and Disassembling the ET 200L Electronics Block Installing the Elec- Attach the electronics block to the terminal block in the following order: tronics Block 1. Insert the electronics block from above into the guideways on the termi- nal block. 2.
  • Page 24: Setting The Et 200L Profibus Address

    Installation Setting the ET 200L PROFIBUS Address Introduction The PROFIBUS address defines the address of the ET 200L distributed I/O device on the PROFIBUS-DP. Location of Rotary The two rotary switches for the PROFIBUS address are located on the elec- Switches tronics block beneath the bus connector.
  • Page 25: Wiring

    Wiring Introduction The ET 200L distributed I/O device has been designed for simple wiring. To this end, the label of the ET 200L distributed I/O device has been made self- explanatory. In this chapter, you will find additional information on wiring the ET 200L distributed I/O device.
  • Page 26: General Rules And Regulations

    Wiring General Rules and Regulations Introduction As a component part of a plant or system, the ET 200L distributed I/O device necessitates observance of special rules and regulations, depending on where it is to be used. This section provides an overview of the most important rules which you have to observe for integrating the ET 200L distributed I/O device in a plant or system.
  • Page 27 Wiring 24 VDC Supply The following table shows the points that you have to take into account in respect of the 24 VDC supply. With ... Pay Attention to... Buildings Outdoor lightning Take lightning protec- protection tion precautions – for tion precautions –...
  • Page 28: Configuring The Electrical Installation

    Wiring Configuring the Electrical Installation Introduction In this section, you will find information on the overall installation of an ET 200L distributed I/O device on a grounded supply (TN-S system). The specific topics discussed are: Circuit-breaking devices, short-circuit and overload protection in accor- dance with DIN VDE 0100 and DIN VDE 0113 Load current power supplies and load circuits.
  • Page 29 Wiring Characteristics of The load current power supply feeds input and output circuits (load circuits) Load Current as well as sensors and actuators. The following table lists the characteristics Power Supplies of load current power supplies that are required in specific applications. Characteristic of Required for ...
  • Page 30: Operating The Et 200L From A Grounded Supply

    Wiring ET 200L in Overall Figure 3-1 shows the location of the ET 200L in the overall system (load cur- Installation rent voltage supply and grounding philosophy) for supply from a TN-S sys- tem. Remark: The arrangement of the power supply connections shown in the fig- ure does not correspond to the actual arrangement but was chosen for the sake of clarity.
  • Page 31 Wiring Protected by cir- n the case of new variants of the following components, the load voltage terminals 1L+, cuit breaker 2L+, and 3L+ used for the sensor power supply of the inputs can be protected using a circuit breaker with a maximum of 6 A (B or C characteristic). Kapitel Komponente MLFB neue Variante...
  • Page 32: Wiring Rules

    Wiring Wiring Rules Rules for Wiring The table below shows you what you must observe when wiring the terminal block and the supplementary terminal. Table 3-2 Pinout of the PROFIBUS-DP Terminal Connection Rules for ... Terminal block Spring Terminal Screw-Type Terminal Suitable cable cross-sections: Solid cables 0.14 to 1.5 mm...
  • Page 33: How The Spring Terminal Works

    Wiring Terminal Block To wire the terminal block (spring terminal), proceed as follows: with Spring Termi- 1. Strip the insulation of the wires down to 11 mm. Remember to: Insert the screwdriver in the lower opening. Insert the cable in the upper opening until the stop. 1.
  • Page 34: Wiring The Et 200L Tb 16L/Tb 32L Terminal Block

    Wiring Wiring the ET 200L TB 16L/TB 32L Terminal Block Introduction When wiring the ET 200L distributed I/O device, we distinguish between the terminal block with its supplementary terminal and the electronics block. The terminal block and, if required, the supplementary terminal carry the wiring.
  • Page 35: Alternative Ways Of Connecting The Voltage Supply

    Wiring Connecting the There are three different ways to connect the voltage supply to the terminal Voltage Supply block. 1st alternative 2nd alternative 3rd alternative Shared voltage supply for Shared voltage supply for Separate voltage supply for groups of channels electronics and groups of each group of channels channels...
  • Page 36: Pinout Of The Profibus-Dp Terminal Connection

    Wiring PROFIBUS-DP Ter- The table below describes the pinout of the 9-pin PROFIBUS-DP terminal minal Connection connection. Table 3-3 Pinout of the PROFIBUS-DP Terminal Connection View Pin No. Signal Name Description – – – – RxD/TxD-P Data line B Request To Send M5V2 Data reference potential (from station) P5V2...
  • Page 37: Commissioning

    Commissioning Contents of the Section Topic Page Chapter Configuration Software Commissioning the ET 200L Configuration Software ET 200L You configure the ET 200L distributed I/O device and SC using the following configuration software. COM ET 200 Windows as of Version 1.0 COM PROFIBUS as of Version 3.0 STEP 7 as of Version 2.1 You will find the name of the type file for the various electronics blocks and...
  • Page 38 Commissioning Commissioning the ET 200L Commissioning Commission the ET 200L distributed I/O device as follows: the ET 200L Step Activity Explanation Install and wire up the ET 200L. You will find detailed instructions on instal- ling and wiring in Chapters 2 and 3. Set the PROFIBUS address of the ET 200L.
  • Page 39 Commissioning Start-up The ET 200L distributed I/O device starts up automatically when the power supply is turned on. A separate switch is not available. During start-up, both LEDs (ON and BF =Bus Fault) are on. The ET 200L distributed I/O device ... Sets the outputs to ”0”.
  • Page 40 Commissioning ET 200L Distributed I/O Device EWA-4NEB 780600902-05...
  • Page 41 Diagnostics Introduction The ET 200L distributed I/O device was designed to make working with and commissioning it as simple as possible. If a failure nevertheless occurs, you can find out what it is by means of LEDs and slave diagnostics. Contents of the Section Topic...
  • Page 42: Diagnostics Using The Led Display

    Diagnostics Diagnostics Diagnostics Using the LEDs Introduction The ET 200L distributed I/O device features the following diagnostic op- tions: LEDs Slave diagnostics (refer to Section 5.2) Status Display Each input and output of the ET 200L distributed I/O device has a status dis- play.
  • Page 43 Diagnostics Diagnostics Slave Diagnostics In Section 5.2 You will find the following topics in this section: Section Topic Page 5.2.1 Structure of the Slave Diagnosis 5.2.2 Structure of Station Statuses 1 to 3, Master Station Number and Manufacturer Identification Definition Diagnostics is the detection and localization of errors.
  • Page 44: Structure Of The Slave Diagnosis

    Diagnostics Diagnostics 5.2.1 Structure of the Slave Diagnosis Introduction The diagnostics of the ET 200L distributed I/O device comply with IEC 61784-1:2002 Ed1 CP 3/1. The slave diagnosis is explained below. Structure of the The slave diagnosis comprises 6 bytes for the ET 200L: Slave Diagnosis Byte 0 Byte 1...
  • Page 45: Structure Of Station Status 1 (Byte 0)

    Diagnostics Diagnostics 5.2.2 Structure of Station Statuses 1 to 3, Master Station Number and Manufacturer Identification Definition of Sta- Station statuses 1 to 3 provide an overview of the status of a DP slave (refer tion Status to Figure 5-1, bytes 0 to 2). Structure of Sta- Station status 1 provides information about the DP slave and is structured as tion Status 1...
  • Page 46: Structure Of Station Status 2 (Byte 1)

    Diagnostics Diagnostics Structure of Sta- Station status 2 provides additional information about the DP slave and is tion Status 2 structured as follows: Table 5-4 Structure of Station Status 2 (Byte 1) Meaning 1: Parameters have to be assigned again to the DP slave. 1: A diagnostic message has been issued.
  • Page 47 General Technical Data What Is General The general technical data consists of the standards and test values with Technical Data? which the ET 200L conforms and which it fulfills, and the test criteria by which the ET 200L distributed I/O device was tested. Contents of the Section Topic...
  • Page 48 Communities: 89/336/EEC Electromagnetic Compatibility Directive 73/23/EEC Low Voltage Directive (for electrical equipment) The EC Declarations of Conformity are available to the relevant authorities at the following address: Siemens Aktiengesellschaft Bereich Automatisierungstechnik A&D AS E 14 Postfach 1963 D-92209 Amberg...
  • Page 49 General Technical Data UL Recognition UL Recognition Mark Underwriters Laboratories (UL) to Standard UL 508, File No. 116536 CSA Certification CSA Certification Mark Canadian Standard Association (CSA) to Standard C22.2 No. 142, File No. LR 48323 FM Approval Factory Mutual Approval Standard Class Number 3611, Class I, Division 2, Group A, B, C, D.
  • Page 50 General Technical Data Electromagnetic Compatibility Definition Electromagnetic compatibility is the ability of an electric device to function satisfactorily in its electromagnetic environment without interfering with this environment. The ET 200L distributed I/O device also meets the requirements, among oth- ers, of the EMC act of the European inner market. A requirement for this is that the ET 200L distributed I/O device meets the specifications and direc- tives concerning electrical installation.
  • Page 51 General Technical Data Sine-Shaped Inter- The following table shows the electromagnetic compatibility of the ET 200L ference distributed I/O device with regard to sine-shaped interference. HF Radiation to ENV 50140 (Corresponds to RF Coupling to IEC 801-3) ENV 50141 (Corre- Electromagnetic RF Field sponds to IEC 801-6) Amplitude-Modulated...
  • Page 52 General Technical Data Shipping and Storage Conditions Conditions The ET 200L distributed I/O device surpasses the requirements of IEC 1131, Part 2, with regard to shipping and storage conditions. The following details apply to modules that are shipped and stored in their original packaging. Type of Condition Admissible Range v 1m...
  • Page 53 General Technical Data Mechanical and Climatic Environmental Conditions Climatic Environ- The following climatic environmental conditions apply: mental Conditions Environmen- Operating Ranges Remarks tal Conditions From 0 to 60 _C Temperature Horizontal wall mounting From 0 to 40 _C All other installation positions Temperature 10 K/h variation...
  • Page 54 General Technical Data Details of Insulation Testing, Safety Class, and Degree of Protection Test Voltage Insulation strength is demonstrated in the routine test with the following test voltage in accordance with IEC 1131, Part 2: Circuits with a Rated Voltage U to Other Test Voltage Circuits or to Ground...
  • Page 55: Rated Voltage Of The Et 200L Distributed I/O Device

    General Technical Data Rated Voltage of the ET 200L Distributed I/O Device Rated Voltage for The ET 200L distributed I/O device operates with the rated voltage and cor- Operation responding tolerances shown in the following table. Table 6-1 Rated Voltage of the ET 200L Distributed I/O Device Rated Voltage Tolerance Range 24 VDC...
  • Page 56 General Technical Data ET 200L Distributed I/O Device 6-10 EWA-4NEB 780600902-05...
  • Page 57: Terminal Blocks And Supplementary Terminals - Technical Data

    Terminal Blocks and Supplementary Terminals – Technical Data Introduction The product spectrum of ET 200L includes various terminal blocks to which you can connect different electronics blocks. This chapter contains the tech- nical data for the terminal blocks and their supplementary terminals. Contents of the Section Subject...
  • Page 58: The Tb 16L Terminal Block With The Electronics Block Clipped On, Dimension Drawing

    Terminal Blocks and Supplementary Terminals – Technical Data Terminal Block TB 16L – 6ES7193-1CH00-0XA0, 6ES7193-1CH10-0XA0 Order Numbers The TB 16L terminal block is available with two types of connection. Connection by means of a screw-type terminal (Order Number 6ES7193-1CH00-0XA0) Connection by means of a spring terminal (Order Number 6ES7193-1CH10-0XA0) Plug-In Electronics You can connect the following electronics blocks to the TB 16L terminal...
  • Page 59: Pinout Of The Tb 16L Terminal Block

    Terminal Blocks and Supplementary Terminals – Technical Data Pinout Table 7-1 shows the pinout of the TB 16L terminal block. Table 7-1 Pinout of the TB 16L Terminal Block Terminal Assignment Inputs Outputs 1 to 8 I0: Signals .0 to .7 Q0: Signals .0 to .7 9 to 16 I1: Signals .0 to .7...
  • Page 60: Terminal Block Tb 32L - 6Es7193-1Cl00-0Xa0, 6Es7193-1Cl10-0Xa0

    Terminal Blocks and Supplementary Terminals – Technical Data Terminal Block TB 32L – 6ES7193-1CL00-0XA0, 6ES7193-1CL10-0XA0 Order Numbers The TB 32L terminal block is available with two types of connection. Connection via screw-type terminal (Order Number 6ES7193-1CL00-0XA0) Connection via spring terminal (Order Number 6ES7193-1CL10-0XA0) Plug-In Electronics You can connect the following electronics blocks to the TB 32L terminal Blocks...
  • Page 61: The Tb 32L Terminal Block With The Electronics Block Clipped On, Dimension Drawing

    Terminal Blocks and Supplementary Terminals – Technical Data Dimension Draw- In Figure 7-2 you can see the dimension drawing of the TB 32L terminal block with the LSC 32 DI 24 V electronics block clipped on. PROFIBUS-DP ET200L DI 32xDC24V SENSOR SUPPLY 33...
  • Page 62: Pinout Of The Tb 32L Terminal Block

    Terminal Blocks and Supplementary Terminals – Technical Data Pinout Table 7-2 shows the pinout of the TB 32L terminal block. Table 7-2 Pinout of the TB 32L Terminal Block Terminal Assignment Inputs Outputs 1 to 8 I0: Signals .0 to .7 Q0: Signals .0 to .7 9 to 16 I1: Signals .0 to .7...
  • Page 63: Supplementary Terminals For The Tb 16L And Tb 32L

    Terminal Blocks and Supplementary Terminals – Technical Data Supplementary Terminals for the TB 16L and TB 32L Definition The supplementary terminals allow you to upgrade the two-wire termination of the ET 200L distributed I/O device to a three- or four-wire termination. Versions Sup- Table 7-3 Supplied Versions of the Supplementary Terminals...
  • Page 64: Tb 16L/Tb 32L Supplementary Terminals, Dimension Drawing

    Terminal Blocks and Supplementary Terminals – Technical Data Dimension Draw- Figure 7-3 shows the dimension drawings for the supplementary terminals. TB 16L single-tier 29.8 40.3 TB 16L double-tier 29.8 40.3 TB 32L single-tier 29.8 40.3 TB 32L double-tier M M M M M M M M 29.8 40.3...
  • Page 65: 200L Electronics Blocks - Technical Data

    ET 200L Electronics Blocks – Technical Data Introduction The components of the ET 200L cannot be upgraded with a Smart Connect. This chapter contains the technical data of the ET 200L electronics blocks. TB´EB Assign- The following table contains the assignment of the ET 200L electronic ment blocks to the terminal blocks.
  • Page 66: View Of The L 16 Di Dc 24 V Electronics Block

    ET 200L Electronics Blocks – Technical Data Electronics Block L 16 DI DC 24 V – 6ES7131-1BH01-0XB0 Characteristics The L 16 DI DC 24 V electronics block has the following characteristics: 16 inputs in two groups, each of eight inputs Rated input voltage of 24 V DC Suitable for switches and proximity switches (BEROs) View...
  • Page 67: Block Diagram Of The L 16 Di Dc 24 V Electronics Block

    ET 200L Electronics Blocks – Technical Data Block Diagram Figure 8-2 shows the block diagram. PROFIBUS-DP connection Internal Electronics power supply Galvanic isolation PROFIBUS address 24 V 24 V 24 V internal Figure 8-2 Block Diagram of the L 16 DI DC 24 V Electronics Block ET 200L Distributed I/O Device EWA-4NEB 780600902-05...
  • Page 68 ET 200L Electronics Blocks – Technical Data Technical Data The following table shows the technical data of the L 16 DI DC 24 V elec- tronics block. Dimensions and Weight Status, Interrupts, Diagnostics Dimensions 60.5 Status display Green LED per channel D (mm) Interrupts None...
  • Page 69: Electronics Block L 16 Do Dc 24 V/0.5 A - 6Es7132-1Bh00-0Xb0

    ET 200L Electronics Blocks – Technical Data Electronics Block L 16 DO DC 24 V/0.5 A – 6ES7132-1BH00-0XB0 Characteristics The L 16 DO DC 24 V/0.5 A electronics block has the following characteris- tics: 16 outputs in two groups, each of eight outputs Output current of 0.5 A per output Rated load voltage of 24 V DC Suitable for solenoids, DC contactors, and indicator lights...
  • Page 70: Block Diagram Of The L 16 Do Dc 24 V/0.5 A Electronics Block

    ET 200L Electronics Blocks – Technical Data Block Diagram Figure 8-4 shows the block diagram. PROFIBUS-DP connection Internal Electronics power supply Galvanic isolation PROFIBUS address 24 V 24 V 24 V internal Figure 8-4 Block diagram of the L 16 DO DC 24 V/0.5 A Electronics Block Technical Data The following table shows the technical data of the L 16 DO DC 24 V/0.5 A electronics block.
  • Page 71 ET 200L Electronics Blocks – Technical Data Voltages, Currents, Potentials Actuator Selection Data Rated supply voltage for 24 V DC Output voltage electronics (4L+, 5L+) At signal ”1” At least L1+ (– 3 V) or Reverse polarity L2+/L3+ (3 V) protection Output current Power failure with-...
  • Page 72: Electronics Block L 32 Di Dc 24 V 6Es7131-1Bl01-0Xb0

    ET 200L Electronics Blocks – Technical Data Electronics Block L 32 DI DC 24 V 6ES7131-1BL01-0XB0 Characteristics The L 32 DI DC 24 V electronics block has the following characteristics: 32 inputs in two groups, each of 16 outputs Rated input voltage of 24 V DC Suitable for switches and proximity switches (BEROs) View The following figure shows a view of the electronics block.
  • Page 73: Block Diagram Of The L 32 Di Dc 24 V Electronics Block

    ET 200L Electronics Blocks – Technical Data Block Diagram Figure 8-6 shows the block diagram. PROFIBUS-DP connection Internal Electronics power supply 24 V 24 V 24 V internal Galvanic isolation PROFIBUS address 17 18 19 20 21 22 23 26 27 28 29 30 31 32 49 50 51 52 53 54 55 58 59 60 61 62 63 64 Figure 8-6...
  • Page 74 ET 200L Electronics Blocks – Technical Data Technical Data The following table shows the technical data of the L 32 DI DC 24 V elec- tronics block. Dimensions and Weight Status, Interrupts, Diagnostics Dimensions 60.5 Status display Green LED per channel D (mm) Interrupts None...
  • Page 75: Electronics Block L 32 Do Dc 24 V/0.5 A -6Es7132-1Bl00-0Xb0

    ET 200L Electronics Blocks – Technical Data Electronics Block L 32 DO DC 24 V/0.5 A – 6ES7132-1BL00-0XB0 Characteristics The L 32 DO DC 24 V/0.5 A electronics block has the following characteris- tics: 32 outputs in two groups, each of 16 outputs Output current of 0.5 A per output Rated load voltage of 24 V DC Suitable for solenoids, DC contactors, and indicator lights...
  • Page 76: Block Diagram Of The L 32 Do Dc 24 V/0.5 A Electronics Block

    ET 200L Electronics Blocks – Technical Data Block Diagram Figure 8-8 shows the block diagram. PROFIBUS-DP connection Internal Electronics power supply 24 V 24 V 24 V Galvanic internal isolation PROFIBUS address 17 18 19 20 21 22 23 26 27 28 29 30 31 32 49 50 51 52 53 54 55 58 59 60 61 62 63 64 Figure 8-8...
  • Page 77 ET 200L Electronics Blocks – Technical Data Galvanic isolation Actuator Selection Data Between channels Output voltage Between channels and At signal ”1” At least L1+ (– 3 V) or PROFIBUS-DP L2+/L3+ (3 V) Insulation tested with 500 V DC Output current Power input At signal ”1”...
  • Page 78: Electronics Block L 16 Di/16 Do Dc 24 V/0.5 A - 6Es7133-1Bl01-0Xb0

    ET 200L Electronics Blocks – Technical Data Electronics Block L 16 DI/16 DO DC 24 V/0.5 A – 6ES7133-1BL01-0XB0 Characteristics The L 16 DI/16 DO DC 24 V/0.5 A electronics block has the following char- acteristics: 16 inputs in a single group of 16 inputs –...
  • Page 79: Block Diagram Of The L 16 Di/16 Do Dc 24 V/0.5 A Electronics Block

    ET 200L Electronics Blocks – Technical Data Block Diagram Figure 8-10 shows the block diagram. PROFIBUS-DP connection Internal power Electronics supply 24 V 24 V 24 V Galvanic internal isolation PROFIBUS address 17 18 19 20 21 22 23 26 27 28 29 30 31 32 49 50 51 52 53 54 55 58 59 60 61 62 63 64 Figure 8-10 Block Diagram of the L 16 DI/16 DO DC 24 V/0.5 A Electronics Block...
  • Page 80 ET 200L Electronics Blocks – Technical Data Aggregate current of outputs (per byte) Input delay Horizontal installation With ”0” after ”1” 2.0 to 4.5 ms Up to 30 _C Max. 4 A With ”1” after ”0” 2.0 to 4.5 ms Up to 40 _C Max.
  • Page 81: Order Numbers

    Order Numbers Introduction Should you require additional components for the ET 200L distributed I/O device or should you wish to upgrade the PROFIBUS, you will find the order numbers here for the corresponding components. We have divided the components into: ET 200L components Accessories for the PROFIBUS with a note on the manuals for the differ- ent PROFIBUS-DP masters and system configuration software...
  • Page 82: Order Numbers For Et 200L Components

    Order Numbers Order Numbers for ET 200L Components Introduction You will find here the order numbers for ET 200L components. Terminal Blocks Table A-1 Terminal Block Order Numbers Description Order Number Terminal block TB 16L, screw-type terminal 6ES7193-1CH00-0XA0 Terminal block TB 16L, spring terminal 6ES7193-1CH10-0XA0 Terminal block TB 32L, screw-type terminal 6ES7193-1CL00-0XA0...
  • Page 83: Labeling Strips 6Es7193-1Bh00-0Xa0

    Order Numbers Labeling strips 16 channels Figure A-1 Labeling Strips 6ES7193-1BH00-0XA0 ET 200L Distributed I/O Device EWA-4NEB 780600902-05...
  • Page 84: Labeling Strips 6Es7193-1Bl00-0Xa0

    Order Numbers Labeling strips 32 channels Figure A-2 Labeling Strips 6ES7193-1BL00-0XA0 ET 200L Distributed I/O Device EWA-4NEB 780600902-05...
  • Page 85: Order Numbers For Profibus Accessories

    Order Numbers Order Numbers for PROFIBUS Accessories Introduction In this section, we have listed the order numbers for PROFIBUS accessories which you require for the ET 200L. Further, you will find notes on the different manuals you will require, de- pending on the PROFIBUS-DP master being used.
  • Page 86: Manuals For Step 7 And Simatic S7

    Order Numbers Manuals for You require one of the manuals listed in Table A-5 to program and commis- STEP 7 and SI- sion the ET 200L with STEP 7. MATIC S7 Table A-5 Manuals for STEP 7 and SIMATIC S7 Manual Contents S7-300 Programmable Controller...
  • Page 87: Type And Device Master Files

    Type and Device Master Files Type File All the properties of a DP slave are stored in a type file. You can integrate the type file of the ET 200L (Table B-4) in COM ET 200 as of Version 4.0, COM ET 200 Windows and STEP 7. Device Master File All slave-specific characteristics are stored in a device master file (GSD file).
  • Page 88: Version Der Projektier-Software

    Type and Device Master Files Configuration The following table shows the version of the configuration software as of Software which the ET 200L are integrated. Table B-1 Version der Projektier-Software Order Number of the COM ET 200 Win- STEP 7 Module dows PROFIBUS...
  • Page 89: Data For Profibus-Dp

    Type and Device Master Files Most Important If you do not have the device master file in front of you, the most important Characteristics characteristics of the ET 200L distributed I/O device are listed here in tabular form. Table B-2 Data for PROFIBUS-DP Characteristic DP Keyword in Accor-...
  • Page 90: Maximum Number Of Inputs And Outputs With The Et 200L

    Type and Device Master Files Inputs and Out- Table B-3 indicates the maximum number of inputs and outputs of the differ- puts with the ent ET 200L electronics blocks: ET 200L Table B-3 Maximum Number of Inputs and Outputs with the ET 200L Electronics Block Maximum Number of Inputs (Bytes)
  • Page 91: Guidelines For Handling Electrostatically Sensitive Devices (Esd)

    Guidelines for Handling Electrostatically Sensitive Devices (ESD) Summary of Sec- In Section You will find On Page tions What is ESD? Electrostatic Charging of Persons General Protective Measures Against Electrostatic Discharge Damage ET 200L Distributed I/O Device EWA-4NEB 780600902-05...
  • Page 92: What Is Esd

    Guidelines for Handling Electrostatically Sensitive Devices (ESD) What is ESD? Definition All electronic modules are equipped with large-scale integrated ICs or com- ponents. Due to their design, these electronic elements are very sensitive to overvoltages and thus to any electrostatic discharge. These Electrostatically Sensitive Devices are commonly referred to by the abbreviation ESD.
  • Page 93: Electrostatic Charging Of Persons

    Guidelines for Handling Electrostatically Sensitive Devices (ESD) Electrostatic Charging of Persons Charging Every person with a non-conductive connection to the electrical potential of its surroundings can be electrostatically charged. Figure C-1 shows you the maximum values for electrostatic voltages which can build up on a person coming into contact with the materials indicated in the figure.
  • Page 94: General Protective Measures Against Electrostatic Discharge

    Guidelines for Handling Electrostatically Sensitive Devices (ESD) General Protective Measures Against Electrostatic Discharge Damage Ensure Sufficient Make sure the personnel, working surfaces and packaging are sufficiently Grounding grounded when handling electrostatically sensitive devices.You can thus avoid electrostatic charging. Avoid Direct You should touch electrostatically sensitive devices only if it is unavoidable Contact (for example, during maintenance work).
  • Page 95: Glossary

    Glossary Aggregate current The aggregate of the currents of all the output channels of a digital output module. Baud rate The baud rate is the speed at which data is transmitted. It specifies the num- ber of bits transmitted per second (baud rate = bit rate). Baud rates of 9.6 kbps to 1.5 Mbps are possible with the ET 200L.
  • Page 96 CPU rather than in the central rack. For example: ET 200L ET 200S ET 200M Other DP slaves manufactured by Siemens or another company The distributed I/O devices are connected to the DP master via the PROFI- BUS-DP bus. Diagnostics Diagnostics is the detection, localization, categorization, indication and anal- ysis of errors, faults, malfunctions and messages.
  • Page 97 CPU 315-2 DP can be DP masters, for example. The distributed I/O devices ET 200B, ET 200C, ET 200M, ET 200L or ET 200U can be DP slaves, as can other DP slaves made by Siemens or other manufacturers.
  • Page 98 Glossary Ground The conductive earth whose electrical potential can be set to zero at any point. Around grounding electrodes, the earth may have a potential other than zero. The term ”reference ground” is frequently used in this connection. Grounding Grounding means to connect an electrically conductive part to the grounding electrode by means of a grounding system.
  • Page 99 Glossary Parameterization Parameterization is the passing of slave parameters from the DP master to the DP slave. Parameters, dy- In contrast to static parameters, the dynamic parameters of modules can be namic changed during operation by calling an SFC in the application program (e.g. limit values of an analog signal input module).
  • Page 100 Glossary A slave cannot exchange data with a ³ master unless requested by the latter Slave to do so. Examples of slaves are all DP slaves, such as ET 200B, ET 200L and ET 200M. SYNC SYNC is a control command of the DP master to a group of DP slaves. By means of the SYNC control command, the DP master causes the DP slave to freeze the statuses of the outputs at their current value.
  • Page 101: Index

    Index Numbers Components of an ET 200L, 1-7 Configuration, Glossary-1 24 VDC supply, 3-3 Configuration software, 4-1 Connect, terminal block, 3-10 Connecting cables, tightening torque, 3-8 Consistent data, Glossary-2 Accessories, order number, A-5 CSA certification, 6-3 Aggregate current, Glossary-1 Applications, 1-3 Assignment of EB to TB, 8-1 Data exchange, 4-3 Definition...
  • Page 102 Index ET 200L and Smart Connect, what is the ET 200L and Smart Connect, 1-3 EB L 16 DI DC 24 V, 8-2 block diagram, 8-3 technical data, 8-4 view, 8-2 EB L 16 DI/16 DO DC 24 V/0.5 A, 8-14 Floating, Glossary-3 block diagram, 8-15 FM approval, 6-3...
  • Page 103 Index Product overview, 1-1 PROFIBUS, Glossary-5 Manual address, Glossary-5 order number location of rotary switch, 2-6 S5, A-6 address modifying, 2-6 S7, A-6 address validity, 2-6 purpose of, iii PROFIBUS address, setting, 2-6 Manufacturer ID, B-4 PROFIBUS drop cable, order number, A-5 definition, 5-6 PROFIBUS-DP terminal connection, 3-12 structure, 5-6...
  • Page 104 Index Supplementary terminal, 7-7 Terminal connection model, 3-11 dimension drawing, 7-8 Test voltage, 6-8 disassembling, 2-3 Tightening torque, connecting cables, 3-8 installing, 2-3 TN system, 3-6 order number, A-2 Training center, iv versions supplied, 7-7 Type file, B-1, Glossary-6 Supply isolating switch, 3-2 Type files, device master files, B-1 Supply voltage, 3-2 SYNC, Glossary-6...

Table of Contents