Installation Tips to Ensure Proper Performance

Before installing, read all directions carefully and contact your dealer for installation support.
WARNING
• Do not exceed maximum operating pressure of 50 psi.
• Do not install automatic or fast shut off valves
downstream of feeder.
• Always install the Perform-Max Feeder AFTER the
heater (if applicable) on the return line.
• Always install any additional sanitizing equipment
AFTER and NEVER BEFORE the Perform-Max Feeder
is installed on the return line.
1) If using a multi-speed pump, run pump for at least
6 hours per day at high speed (at least 40 gpm).
If the pump will run on low speed 24 hours
per day or less than 6 hours per day on
high speed, you must bleed the air while
the pump is on by unscrewing the cap
knob until water appears. Then screw the
knob back on. Repeat this process each
time the cap is removed for any reason.
2) Install Perform-Max Feeder with
4-8 psi back pressure.
Lower back pressures could result in under
chlorination. Change the eyeball fi ttings in
the return jets to a smaller size to increase
back pressure. Contact King Technology
at 800-222-0169 for a specially designed
Perform-Max Feeder pressure gauge to
determine back pressure at pool start-up.
3) Special installation Requirements:
IMPORTANT: Over chlorination or damage to the Perform-
Max Feeder or other equipment could result if special
installations A, B or C are not used in these situations.
• If water fl ow is higher than 80 gallons per minute
(gpm), see diagram A.
• If an in-fl oor cleaner is included with pool,
see diagram B, with two options. Preferred
installation is Option 1 with two separate lines.
• If set-up is a pool and spa combination with
common equipment, see diagram C.
Questions? Call Customer Service at 800-222-0169
Monday thru Friday, 8 am to 5 pm central time.
6
A. With High Flow Rate
Install T-fi ttings exactly as shown.
SUCTION
FROM
POOL/SPA
B. With In-Floor Cleaner - TWO OPTIONS
OPTION 1- A Two-Line Installation
The best option is to have two lines. One line with pump, fi lter, heater
and Perform-Max Feeder and a second line with a separate pump for the
in-fl oor cleaning system (fi lter optional).
Line 1
Line 2
PN #01-22-4000
OPTION 2 - A 3-Way Valve Installation
C. Pool and Spillover Spa Combination
SUCTION
FROM
POOL/SPA
(greater than 80 gpm)
CHECK
VALVE
HEATER
Flow
PUMP
Flow
PUMP
3-way manual valve or 3-way motor valve plus controls
9
9
PUMP
M
9
CHECK VALVE
PUMP
Perform-Max
Feeder
POOL
TO
Perform-Max
Feeder
M
POOL RETURN
POOL WATER LEVEL
IN-FLOOR
CLEANER VALVE
POOL WATER LEVEL
Perform-Max
IN-FLOOR
Feeder
CLEANER VALVE
9
9
POOL WATER LEVEL
3-WAY VALVE
Perform-Max
Feeder