Adjusting Timing Controls

Note: All adjustments and changes to this unit's timing must be made with the lid lock
disengaged and the lid open. DO NOT use the machine with the lid lock engaged.
1. To set and adjust the timing controls, press the "Set" button on the front control panel.
You can repress the "Set" button to cycle through the settings for Vacuum or Sealing.
Once selected, the current time setting will appear on the LED Screen.
The unit's standard settings are:
Vacuum Time – 40 Seconds
Sealing Time – 1.2 Seconds
2. Once the setting is selected, you can increase or decrease the time by pressing
the "Up" or "Down" arrow buttons accordingly. The new time settings will appear on
the screen and be saved to the machine.
Note: For setting the Vacuum time, you can use filler plates to occupy space in the
chamber, leaving less air to be removed from the chamber, thus decreasing the overall
vacuuming time.
Note: For setting the Sealing time, it is recommended you increase
the seal time by small increments of 0.1 to avoid over-sealing or melting the bag.
3. Upon finishing setting the timing controls, press the "Set" button until no lights on the
control panel are illuminated. The machine will not operate until all lights are off.

Product Function

Chamber

SEAL BAR
6.
PRESSURE GAUGE
CONTROL PANEL
CASTERS
CHAMBER
LID
LIDLOCK
POWER SWITCH
GASKET
SEAL STRAP