P r i m a L u c e L a b i S r l
Advanced Settings:
In the first set of commands, the operating currents of the SESTO SENSO 2 motor are reported, the values that can be set
range from 0 to 10.
•
Acceleration: set the current in acceleration ramp
•
Run: set the current after acceleration ramp during RUN
•
Deceleration: set the current in deceleration ramp
In the second set of commands ("Speed settings), the SESTO SENSO 2 motor movement speed parameters are set.
•
Acceleration: set the acceleration during starting ramp (Range from 0 to 10)
•
Run: set the speed value after acceleration ramp (Range from 0 to 10)
•
Deceleration: set deceleration value after slowdown ramp (Range from 0 to 10)
•
Hold: set the hold current, when the motor is stopped
The third option allows you to activate the Hold current.
NOTE: if the focus micrometer reduction system has slippages between the micrometer pin and focuser shaft, you can
solve this problem by setting the Acceleration, Run, and Deceleration (in Speed Settings) to 1.