250
MICRO SLAVE
251
KM OPEN
252
KS OPEN
253
KM CLOSED
254
KS CLOSED
BL-J1-0315 - 11-19-2019
It occurs when the information on the
status bus between the main uC and
the slave uC is frozen to the 0xFF
value (the slave uC does not update
the status bus configuration).
This alarm occurs if the slave uC detects
the safety contact, of the main uC, is
open when expected to be closed.
This alarm occurs if the main uC detects
the safety contact, of the slave uC, is
open when expected to be closed.
This alarm occurs at key on if the slave
uC detects the safety contact, of the
main uC, is closed prior to being com-
manded.
This alarm occurs if the main uC detects
the safety contact, of the slave uC to
be closed prior to being commanded.
Replace the controller.
Replace the controller.
Replace the controller.
This alarm occurs if the connection
CNA#5 (K1) is around a voltage of 12
Vdc when switching on the key. In fact,
when the safety contacts are open, K1
is expected to be connected to a bat-
tery voltage (not 12 V). Search for a
harness problem or replace the con-
troller.
This alarm occurs if the connection
CNA#4 (NK1) is around a voltage of 12
Vdc when switching on the key. In fact,
when the safety contacts are open to a
minus battery voltage (not 12 V).
Search for a harness problem or
replace the controller.