Fuel Setup - Dakota Digital VFD3 Installation And Operation Manual

Vacuum fluorescent digital dashboard
Table of Contents

Advertisement

FUEL SETUP

The control box can read 7 different types of preset fuel senders and can also be
programmed for a custom fuel sender setup. Press and hold SW 1 switch while turning the key
on. Release the switch. When "FUEL" is displayed, press the switch again and then release it.
The message display should switch between "SENDER", "CUSTOM", and "TEST".
Sender Selection
When "SENDER" is displayed press and release the switch.
Press and release the switch until the desired setting is shown. The preset types are
listed in the table below.
Press and hold the switch until "DONE" is displayed.
Sender type
GM 0-30 ohm
GM 0-90 ohm
GM 40-250 ohm
FORD 73-10 ohm
FORD 20-150 ohm
VDO 10-180 ohm
SW/SUN 33-240
User programmed
Custom Fuel setup
You will either need to have the sender out of the tank, or begin with the tank empty and
add fuel during the setup.
When "CUSTOM" is displayed press and release the switch.
The speed display will show the current sender resistance seen by the control box.
The message display will show "SET 00". Move the float to the empty position and then
press and release the switch.
The message display will show "SET 33". Release the switch and move the float to 1/3
full and then press and release the switch.
The message display will show "SET 66". Release the switch and move the float to 2/3
full and then press and release the switch.
The message display will show "SET 99". Release the switch and move the float to the
full position and then press and release the switch. The new sender is now stored under
the "CUSTOM" sender selection.
The message display will show begin going back through the main menu. When "FUEL"
is displayed, press and release the switch.
When "SENDER" is displayed press and release the switch.
The current sender setting will now be displayed. Press and release the switch until
"CUSTOM" is displayed.
Press and hold the switch until "DONE" is displayed.
Menu
Empty R
GM 30
0 ohms
GM 90
0 ohms
GM 250
40 ohms
F 73
73 ohms
F 150
20 ohms
V 180
10 ohms
SW 33
240 ohms
CUSTOM
User settable
15
Full R
30 ohms
90 ohms
249 ohms
10 ohms
150 ohms
180 ohms
33 ohms
User settable
650066

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ret

Table of Contents