Download Print this page

Comtrol DeviceMaster 500 Manual page 7

Device server. laser scanner

Advertisement

Connecting the
Power and Verifying
Installation
Caution
Installing the DeviceMaster 500 and the SICK LMS Scanner (Windows): 2000472 Rev. C
Use the following procedure to wire the power terminal connector and connect the
DeviceMaster 500 to a power source.
1. Connect the screw terminal power connector to the wires on the power supply
as displayed. The power supply must conform to the specifications for the
DeviceMaster 500 embedded.
Power Supply†
Output voltage
Current
Power
† Any power supply that meets current consumption, voltage,
power, and connector pinouts requirements can be used.
Observe proper ESD techniques when connecting and disconnecting
the DeviceMaster 500.
2. Use a small flat head screw to lock the wires into place.
3. Plug the screw
terminal power
connector into
JP1 on the
DeviceMaster
500 by aligning
the scalloped
sides.
4. Apply power to
the DeviceMaster
500.
5. Verify the Status
LED has
completed the
boot cycle and
network
connection for the
DeviceMaster
500 is functioning properly using the table below.
The LEDs are located between the RJ45 connector and the power terminal
block.
When lit, the Status LED (D1) on the DeviceMaster 500
indicates the devices is fully powered and has completed the
boot cycle.
Note: The Status LED flashes for approximately 15 seconds
Status
When lit, the Link/Act LED (D2) indicates a working
Link/Act
Ethernet connection.
Duplex
When lit, the Duplex (D3) LED indicates full-duplex activity.
When lit, the 100 (D4) LED indicates a working 100 MB
Ethernet connection (100 MB network, only). If the LED is
100
not lit, it indicates a 10 MB Ethernet connection.
Go to
Software Installation
Connecting the Power and Verifying Installation
Specifications
5-30VDC
100 mA (Min.) @ 24VDC
2.5 W
LED Descriptions
while booting. When the bootloader completes the
cycle, the LED has a solid, steady light. When the
Bootloader completes the cycle, the LED has a solid,
steady light that blinks approximately every 30
seconds.
on Page 9 to complete the installation.
LEDs
JP1
7

Advertisement

loading

This manual is also suitable for: