1-Port Custom Embedded Bulk (99474-9) Installation
1-Port Custom Embedded Bulk (99474-9) Installation
Building the Serial
Ribbon Cable
4
LED Descriptions 1-Port Enclosed
If the LED is lit, it indicates that the DeviceMaster 500 has
power and it has completed the boot cycle.
Note: The Status LED flashes while booting and it takes
Status
Go to
Software Installation
Use the following procedure to set up the 1-port custom embedded bulk
DeviceMaster 500 and LMS scanner at 500K baud.
•
If necessary, build the serial ribbon cable.
•
Mount the DeviceMaster 500 and optionally install light pipes (Page 5).
•
Attach the network and serial cables (Page 6).
•
Connect the power and verify installation (Page 7).
Use the following information to build a DB9 serial ribbon cable to connect to the
DeviceMaster 500 1-Port embedded IDC10 connector (J3).
10-Pin
Socket
J3 Header
Installing the DeviceMaster 500 and the SICK LMS Scanner (Windows): 2000472 Rev. C
approximately 15 seconds for the Bootloader to
complete the boot cycle. When the Bootloader
completes the cycle, the LED has a solid, steady light
that blinks approximately every 30 seconds.
on Page 9 to complete the installation.
9 10
Ribbon Cable
1 2
J3
RS-232
RS-422
1
CD
Not used Not used
2
DSR
Not used Not used
3
RxD
RxD-
4
RTS
TxD+
5
TxD
TxD-
6
CTS
RxD+
7
DTR
Not used Not used
8
RI
Not used Not used
9
GND
Not used Not used
10
Not connected
Pin 5 Pin 9
DB9
Male
Pin 6
Pin 1
RS-485
Not used
TRX+
TRX-
Not used