Toro Multi Pro ExcelaRate 5800-G Operator's Manual page 76

Turf sprayer with spray system
Table of Contents

Advertisement

5.
Installing the Section-Manifold Valve (page
80)
6.
Installing the Valve Actuator (page 81)
Removing the Valve Actuator
1.
Position the sprayer on a level surface, set the
parking brake, stop the pump, stop the engine,
and remove the key from the starter switch.
2.
Remove the retainer that secures the actuator
to the manifold valve for the section valve or
agitation valve
(Figure
Note:
Squeeze the 2 legs of the retainer
together while pushing it down.
Note:
Retain the actuator and retainer for
installation in
Installing the Valve Actuator (page
81).
Figure 96
Section Valve Actuator Shown (the agitation-valve actuator
1. Actuator (section valve)
2. Retainer
3.
Remove the actuator from the manifold valve.
96).
is similar)
3. Stem port
Removing the Agitation-Manifold
Valve
1.
Remove the clamps, gaskets, quick connect,
and quick-connect pin that secure the manifold
for the agitation valve to the agitation-bypass
valve, pressure-filter head, reducer coupling,
and adapter fitting (agitation-throttle valve) as
shown in
Note:
Retain the clamps, gaskets, quick
connect, and quick-connect pin for installation in
Installing the Agitation-Manifold Valve (page
1. Quick-connect pin
g032545
2. Flange (pressure-filter
head)
3. Manifold (agitation valve)
4. Flange (agitation-bypass
valve)
5. Flange (reducer coupling)
2.
Remove the agitation-valve manifold from the
machine
1. Agitation-valve manifold
76
Figure
97.
Figure 97
Agitation Valve
6. Flange (adapter
fitting—agitation-throttle
valve)
7. Quick connect
8. Gasket
9. Flange clamp
(Figure
98).
Figure 98
80).
g032546
g032547