MAINTENANCE

PRECAUTIONS FOR SCR ASSEMBLY

Be careful for the high temperature parts when performing inspection and maintenance. Even after the engine
stops the parts around SCR device may be at high temperature.

DUSTY JOBSITES

When working at dusty jobsites, observe the following.
Clean the radiator fins and other parts of the heat exchange equipment more frequently, and take care not
to let the fins become clogged.
Replace the fuel filter more frequently.
Clean electrical components, especially the starting motor and alternator, to avoid accumulation of dust.
When checking and replacing the oil or filters, move the machine to a place where there is no dust and take
care to prevent dust from entering the system.

AVOID MIXING OIL

Never mix different brand or grade of oil. If a different brand or grade of oil has to be added, drain the old oil and
replace all the oil with the new brand or grade of oil.

PRECAUTIONS FOR OPENING AND CLOSING RADIATOR GRILLE

Stop the engine before opening or closing the radiator grille, and open or close it while the fan is stopped. If
you touch the fan when it is rotating, it will cause serious personal injury or death.
Be careful not to get your fingers caught between the tank, etc. when opening or closing the radiator grille.
Check that the lock is securely set when opening the radiator grille. Check that there is no abnormality in
the lock or link portion as well.
When opening the radiator grille, be careful not to hit your head, etc. against it.
Check the hoses and piping which move together with the radiator grille for cracks and damage.

LOCK INSPECTION COVERS

Lock inspection cover securely into position with the lock bar, etc. If inspection or maintenance is performed with
inspection cover not locked in position, there is a danger that it may be suddenly shut by the wind and cause
personal injury.

BLEED AIR FROM HYDRAULIC CIRCUIT

When hydraulic equipment is repaired or replaced, or the hydraulic piping is disconnected, the air must be bled
from the circuit. For bleeding air, see "METHOD FOR BLEEDING AIR FROM HYDRAULIC CIRCUIT".

PRECAUTIONS WHEN INSTALLING HYDRAULIC HOSES

When removing parts at locations where there are O-rings or gasket seals, clean the mounting surface, and
replace them with new parts.
When doing this, be careful not to forget to assemble O-rings and gaskets.
When installing the hoses, do not twist them or bend them sharply.
If they are installed so, their service life will be extremely shortened and they may be damaged.