Troubleshooting Flowchart; Solution - H3C S5150-EI Series Troubleshooting Manual

Hide thumbs Also See for S5150-EI Series:
Table of Contents

Advertisement

Troubleshooting flowchart

Figure 3 Troubleshooting IRF fabric establishment failure
fewer than the upper limit?
or physical IRF connections
10-Gbps IRF links used?
Transceiver modules at link ends are
Same software version?

Solution

To resolve the problem:
1.
Verify that the number of member devices does not exceed the upper limit (varies by software
version).
If you are adding a new member device to an existing IRF fabric or merging IRF fabrics, use the
display irf command to identify the number of member devices in the IRF fabrics. If the total
number of member devices exceeds the upper limit, the IRF setup will fail.
IRF setup
failure
Number of members
Yes
Member ID unique?
Yes
IRF port bindings
correct?
Yes
Yes
(Optional.)
the same type?
Yes
IRF links up?
Yes
Yes
Contact H3C
Support
No
You cannot add devices to the
IRF fabric
No
Assign a unique member ID to
each member device
No
Modify IRF port bindings or
reconnect physical ports
No
Replace with 10-Gbps
transceiver modules/cables
No
Replace the transceiver
modules to be the same type
No
Bring up the IRF links/activate
IRF port configuration
No
Upgrade software to the same
version in the fabric
13
Yes
Resolved?
No
Yes
Resolved?
No
Yes
Resolved?
No
Yes
Resolved?
No
Yes
Resolved?
No
Yes
Resolved?
No
End

Advertisement

Table of Contents
loading

Table of Contents