Comfort Flame Barkley Series Installation And Operation Instructions Manual

Vent free universal firebox system

Advertisement

Quick Links

WELCOME HOME TO WARMTH
P900564-00
P/N 900564-00 Rev. N/C 09/2015
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
WARNING: Carefully review the instructions supplied with the decorative type unvented room heater for
the minimum fireplace size requirement.
Do not install the appliance in this firebox, unless this firebox meets the minimum dimensions required for
the installation.
This appliance may be installed in an aftermarket permanently located, manufactured (mobile) home,
where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the
rating plate. This appliance is not convertible for use with other gases.
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or
property damage. Refer to this manual for correct installation and operational procedures. For assistance or
additional information consult a qualified installer, service agency or the gas supplier.
WARNING: For use only with a listed, gas-fired unvented decorative room heater not to exceed 40,000
Btu/H.
Do not build a wood fire.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious injury, death, or property damage.
— Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
— Installation and service must be performed by a qualified installer, service agency or the gas supplier.
TM
PFS
®
US
Report No. F09-130
Installation and Operation Instructions
Comfort Flame™ Vent Free Barkley Series
Universal Firebox System
BarkleySTXWS
BarkleySTYWS
Models

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Barkley Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Comfort Flame Barkley Series

  • Page 1 Installation and Operation Instructions Comfort Flame™ Vent Free Barkley Series WELCOME HOME TO WARMTH Universal Firebox System Models BarkleySTXWS P900564-00 ® BarkleySTYWS P/N 900564-00 Rev. N/C 09/2015 Report No. F09-130 INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.
  • Page 2: Table Of Contents

    Thank you for your purchase. We appreciate your TABLE OF CONTENTS business! Safety ..................... 2 Please carefully read and follow all instructions in this manual. Pay Local Codes ................... 3 special attention to all warnings and safety information. Requirements for the Commonwealth of Massachusetts....3 Following these safety, care, and operation instructions will help Unpacking ..................
  • Page 3: Local Codes

    SAFETY Continued COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS These appliances are approved for installation in the US state of You must operate this fireplace with the provided Massachusetts if the following additional requirements are met: fireplace screen, hood and brick liner in place. Make •...
  • Page 4: Unpacking

    UNPACKING PRODUCT FEATURES 1. Remove all protective packaging from inside firebox. Carefully lift OPERATION the firebox off the bottom corrugated tray. This firebox is designed for use with approved ANS Z21.11.2 decora- 2. Carton should contain 2 deflective hoods and hardware packet in tive type unvented room appliances.
  • Page 5: Product Specifications

    PRODUCT SPECIFICATIONS " 24" 1/2" 5/8" " " 3" " " 4" " " 40" " " " " " 12" Figure 1 - Dual-Sided Firebox LOCATING FIREBOX PLANNING Plan where you will install the firebox. This will save time and money later when you install the firebox.
  • Page 6: Air For Combustion And Ventilation

    AIR FOR COMBUSTION AND VENTILATION Btu/hr (4.8 m per kw) of the aggregate input rating of all appliances WARNING: This appliance shall not be installed in installed in that space and an unconfined space as a space whose a room or space unless the required volume of indoor volume is not less than 50 cubic feet per 1,000 Btu/hr (4.8 m kw) of the aggregate input rating of all appliances installed in that combustion air is provided by the method described...
  • Page 7 AIR FOR COMBUSTION AND VENTILATION Continued You must provide additional fresh air. Your options are as follows: Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts. You must A. Rework work sheet, adding the space of an adjoining room. If the provide two permanent openings: one within 12"...
  • Page 8: Installation

    INSTALLATION Carefully follow the instructions below. This will ensure safe instal- NOTICE: This firebox in combination with unvented lation. log sets are intended for use as supplemental heat. Minimum Wall and Ceiling Clearances Use along with your primary heating system. Do not A.
  • Page 9 INSTALLATION Continued Mantel Clearances for Built-In Installation 3. If a raised platform is to be constructed, ceiling clearances must If placing custom mantel above built-in firebox, you must meet be maintained. the minimum allowable clearance between mantel shelf and top of 4.
  • Page 10 INSTALLATION Continued WARNING: Do not allow any combustible materi- Nails or als to overlap the firebox front facing (see Figure 9). Wood Screws IMPORTANT: Noncombustible materials such as brick, tile, etc. may overlap the front facing, but should never cover any necessary openings like louvered slots.
  • Page 11 INSTALLATION Continued Firebrick Floor The incoming gas line may be routed into the vent-free firebox either from the left or right hand sides (see Figure 11). Remove the gas line cover plate from the vent-free firebox’s outer surround at the location to be used.
  • Page 12 INSTALLATION Continued GAS SUPPLY TESTING Gas Connection Access Hole Note: This section is intended as a guide for qualified technicians installing gas to this vent-free firebox. CAUTION: Do not connect vent-free appliance be- fore pressure testing gas piping. Damage to gas valve may result and an unsafe condition may be caused.
  • Page 13 INSTALLATION Continued 5. Apply gentle force between hook and loop mounting strips to seat WARNING: Never touch blower wheel while in blower. operation. 6. Remove control knob and lock nut from blower speed control shaft. 10. Turn blower on and check for proper operation. 7.
  • Page 14 OPERATING GUIDELINES AND MAINTENANCE INSTRUCTIONS When lit for the first time, a vent-free log appliance will emit a slight due to excessive lint from carpeting, pet hair, etc. It is imperative that odor for about an hour or two. This is a normal occurrence which is the control compartments, burners and circulating air passageways due to the “curing”...
  • Page 15: Service Hints

    SERVICE HINTS REPLACEMENT PARTS See Pages 16 to 17 for a complete replacement parts list. Use only When Gas Pressure Is Too Low parts supplied from the manufacturer. • pilot will not stay lit Normally, all parts should be ordered through your IHP distributor •...
  • Page 16: Parts

    PARTS CATALOG NO. MODEL F2564 BarkleySTXWS F2565 BarkleySTYWS 17** 10** 16** 16** 16** 11** 16** 16** 16** 16** 16** **These items are used on both sides of fireplace. Comfortflame.US.com 900564-00NC...
  • Page 17 PARTS This list contains replaceable parts used in your firebox. When ordering parts, follow the instructions listed under Replacement Parts on page 15 of this manual. WARNING: Contact an IHP dealer to obtain any of these parts. Never use substitute materials not approved by IHP.
  • Page 18 NOTES ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ Comfortflame.US.com 900564-00NC...
  • Page 19: Warranty

    THE WARRANTY Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your Comfort Flame™ Brand gas fi replace or insert ("Product") to be free from defects in materi- als and workmanship at the time of manufacture. The Product body and fi rebox carry the 20 Year Limited Warranty. Ceramic glass carries the 20 Year Limited Warranty against thermal breakage only.
  • Page 20 WARRANTY KEEP THIS WARRANTY Model Number Serial Number Date Installed Dealer's Name Dealer's Phone Number Keep receipt for warranty verification Innovative Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information.

This manual is also suitable for:

BarkleystxwsBarkleystyws

Table of Contents