ABB UNO-2.0-I-OUTD Product Manual page 76

Solar inverters 2.0 to 2.5 kw
Hide thumbs Also See for UNO-2.0-I-OUTD:
Table of Contents

Advertisement

INVERTER RUN
N.C.
Relay State: Idle
N.O.
ERROR OCCURENCY
ERROR MESSAGE
t=15s
N.C.
Relay State: Switched
N.O.
GRID RECONNECTION
t=based on Country Standard
N.C.
Relay State: Idle
N.O.
ERROR
Yes
No
STILL
PRESENT
INVERTER RUN
N.C.
Relay State: Idle
N.O.
SELECTED
ERROR/WARNING
OCCURENCY
ERROR MESSAGE
t=15s
N.C.
Relay State: Switched
N.O.
GRID RECONNECTION
t=based on Country Standard
N.C.
Relay State: Idle
N.O.
ERROR/WARNING
Yes
No
STILL
PRESENT
For both configurable relay operating modes "ALARM" and "ALA". CONF." the following con-
siderations apply:
If the alarm condition is persistent, the alarm contact cyclically switches from its resting state
to its activated state.
In the presence of W003 signalling (Grid Fail – Network parameters out of tolerance), the
alarm contact switches to then reset itself at the end of the alarm signal. This means that
during the absence of grid voltage (display message "Vac Absent") the alarm contact remains
in its resting position.
• Alarm with reset at the end of the alarm signalling process (display
text "ALARM"):
The relay is activated (state: switched) whenever an error is present
(code Exxx) on the inverter; this does not apply to warnings (Warning
– code Wxxx). The alarm returns to its resting position when the alarm
signal ends, i.e. before the inverter checks the grid parameters after the
alarm state. This is because grid control state is not an alarm state but a
state of normal operation.
Alarms for which the relay is activated
E001
E002
E007
E010
E015
E016
E021
E022
E031
E032
E050
E051
E057
E058
• Configurable alarm with reset at the end of the alarm signalling
process (display text "Alarm Conf.")
The relay is activated (state: switched) whenever an error is present
(code Exxx) or a warning (code Wxxx) from those selected from the list in
the dedicated submenu. The contact returns to its resting position when
the alarm signal ends, i.e. before the inverter checks the grid after the
alarm state. This is because grid control state is not an alarm state but a
state of normal operation.
Selectable alarms for which the relay is activated
E001
E002
E007
E010
E017
E018
E023
E026
E031
E032
E051
E053
E058
W001
W011
W017
W023
W024
- 76 -
E003
E004
E005
E011
E012
E013
E017
E018
E019
E023
E026
E029
E033
E034
E046
E053
E054
E055
W003
E003
E004
E005
E011
E013
E014
E019
E020
E021
E027
E028
E029
E033
E034
E046
E054
E055
E056
W002
W003
W008
W018
W019
W021
W025
W026
7 - Operation
E006
E014
E020
E030
E049
E056
E006
E015
E022
E030
E050
E057
W009
W022
Ground fault