Wall Mount Steel Fountains
INSTALLER
These series fountains are among the easiest to install Fountains on the market
today. To assure you install these models easily and correctly,
PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE
INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH
PLUMBING, ELECTRICAL, AND OTHER APPLICABLE CODES. After installation,
leave these instructions with the Fountain for future reference.
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO
WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY
OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK
INTO A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN
INCREASE IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING
THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER
SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING
PLUMBING SYSTEM.
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE IS
TUBE TO ATTACH
SECURED
IN POSITION
FIG. 1
HT - EBP*E HT - SBP*E HT - SEBP*K HT - ESBP*K
IMPORTANT
PUSH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
Page 1
3/8" O.D. UNPLATED
1/4" O.D. TUBE
COPPER TUBE CONNECT
WATER INLET
COLD WATER SUPPLY
TO COOLER
NOTE: WATER FLOW
DIRECTION
FIG. 2
BUILDING WATER INLET
SERVICE STOP
(NOT FURNISHED)
97086C (Rev. B - 4/98)

Advertisement

loading

Summary of Contents for Halsey Taylor HT-EBP E Series

  • Page 1 HT - EBP*E HT - SBP*E HT - SEBP*K HT - ESBP*K Halsey Taylor Owners Manual Wall Mount Steel Fountains INSTALLER These series fountains are among the easiest to install Fountains on the market today. To assure you install these models easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION.
  • Page 2 HT - EBP*E HT - SBP*E HT - SEBP*K HT - ESBP*K HT - EBP/SBP/SEBP/ESBP COOLER INSTALLATION 1. Wall should already be framed for the fountain using the rough-in dimensions shown in Fig’s. 3,4,5, or 6. Shown dimensions pertain to installation location (framing must support up to 150 lbs.
  • Page 3 HT - EBP FIG. 3 LEGEND: A = 3/8” O.D. UNPLATED COPPER TUBE CONNECT (WATER SUPPLY) B = 1-1/4” O.D. WASTE TUBE (ELBOW AND TRAP NOT PROVIDED)
  • Page 4 HT - SBP FIG. 4 LEGEND: A = 3/8” O.D. UNPLATED COPPER TUBE CONNECT (WATER SUPPLY) B = 1-1/4” O.D. WASTE TUBE (ELBOW AND TRAP NOT PROVIDED)
  • Page 5 HT - EBP*E HT - SBP*E HT - SEBP*K HT - ESBP*K HT - SEBP FIG. 5 LEGEND: A = 3/8” O.D. UNPLATED COPPER TUBE CONNECT (WATER SUPPLY) B = 1-1/4” O.D. WASTE TUBE (ELBOW AND TRAP NOT PROVIDED) Page 5 97086C (Rev.
  • Page 6 HT - EBP*E HT - SBP*E HT - SEBP*K HT - ESBP*K HT - ESBP FIG. 6 LEGEND: A = 3/8” O.D. UNPLATED COPPER TUBE CONNECT (WATER SUPPLY) B = 1-1/4” O.D. WASTE TUBE (ELBOW AND TRAP NOT PROVIDED) 97086C (Rev. B - 4/98) Page 6...
  • Page 7 HT - EBP*E HT - SBP*E HT - SEBP*K HT - ESBP*K FIG. 7 ITEMIZED PARTS LIST ITEM NO. PART NO. DESCRIPTION 26936C Push Lever Assy Mounting Bracket Assy 26935C 27237C Bracket - Pushbar Lever Rod 75517C 70378C Pushbar Rod Spring Clip 75555C 70856C...
  • Page 8: Troubleshooting And Maintenance

    HT - EBP*E HT - SBP*E HT - SEBP*K HT - ESBP*K ITEMIZED PARTS LIST ITEM NO. PART NO. DESCRIPTION Bubbler-Satin 51546C TROUBLE SHOOTING & MAINTENANCE 45397C Bubbler-Golden Bronzetone Tube Assy-Bubbler 66318C 10080C Nipple-Bubbler (Included w/Item No.2) Orifice Assy: Mineral deposits on orifice can cause water flow to spurt or Gasket-Bubbler (2-Req’d) 100322740560 not regulate.